References
All references
Mixed industrial estate · 4,500 m³/day · India
BOD and COD removal from industrial estate effluent by MBBR, sand and carbon filtration
- Oil and grease removed
- 93%
- Phosphorus removed
- 65%
For more information, contact us
Municipal wastewater · 34,000 m³/day capacity · India
Polishing UASB-treated sewage for solids and sulfide in a final polishing pond
- Sulfide removed
- 66%
- Suspended solids removed
- 41%
For more information, contact us
Municipal wastewater · 38,000 m³/day capacity · India
Polishing UASB-treated sewage for BOD and COD in polishing ponds
- BOD removed
- 49%
- COD removed
- 45%
For more information, contact us
Municipal wastewater · 433,820 m³/day · Taiwan
Nitrogen removal from city sewage by step-feed anoxic and aerobic activated sludge
- BOD removed
- 92%
- COD removed
- 89%
For more information, contact us
Municipal wastewater · 84,000 m³/day · Thailand
Nitrogen removal from weak, carbon-poor sewage by step-feed anoxic and aerobic activated sludge
- Suspended solids removed
- 83%
- BOD removed
- 83%
For more information, contact us
Brewery · 1,550 m³/day capacity · Ethiopia
COD and solids removal from brewery wastewater by UASB reactor and post-aeration
- COD removed
- 97%
- Suspended solids removed
- 96%
For more information, contact us
Mixed industrial estate · 2,500 m³/day · India
COD and solids removal from electroplating estate wastewater by flocculation and tube settlers
- Oil and grease removed
- 88%
- Fluoride removed
- 75%
For more information, contact us
Mixed industrial estate · 3,500 m³/day · India
COD and oil removal from industrial estate wastewater by tube settlers and media filtration
- Oil and grease removed
- 84%
- Suspended solids removed
- 55%
For more information, contact us
Municipal wastewater · 27,000 m³/day capacity · India
Polishing UASB-treated sewage for BOD and suspended solids in final polishing ponds
- Ammonia removed
- 51%
- Suspended solids removed
- 49%
For more information, contact us
Municipal wastewater · 13,000 m³/day · South Africa
Turbidity and COD removal from sewage by lime dosing, settling and biological filters
- Turbidity removed
- 89%
- Aluminium removed
- 68%
For more information, contact us
Municipal wastewater · 122,216 m³/day · Turkey
Nitrogen and phosphorus removal from sewage by anaerobic, anoxic and aerobic activated sludge
- Ammonia removed
- 99%
- BOD removed
- 95%
For more information, contact us
Textile · 3,600 m³/day · Cuba
COD and BOD removal from textile mill wastewater by an undersized activated sludge plant
- Total nitrogen removed
- 97%
- BOD removed
- 86%
For more information, contact us
Brine · 382 m³/day · United States
Shrinking the concentrate from municipal water reuse by high-recovery closed-circuit RO
- Sulfate removed
- 99.7%
- Chloride removed
- 96%
For more information, contact usPilot
Food processing · 427 m³/day · India
Oil and grease and COD removal at a buffalo abattoir by air flotation and activated sludge
- Ammonia removed
- 99.4%
- BOD removed
- 95%
For more information, contact us
Food processing · 254 m³/day · India
BOD and solids removal at a buffalo abattoir by air flotation and a sequencing batch reactor
- Suspended solids removed
- 99.1%
- BOD removed
- 98%
For more information, contact us
Food processing · 353 m³/day · India
COD and BOD removal at a buffalo abattoir by chemical dosing, settling and activated sludge
- Suspended solids removed
- 99%
- BOD removed
- 98%
For more information, contact us
Landfill leachate · 150 m³/day capacity · United Kingdom
Ammonia and COD removal from landfill leachate by a sequencing batch reactor and a reed bed
- Ammonia removed
- 99.9%
- Alkalinity removed
- 70%
For more information, contact us
Municipal wastewater · 29,400 m³/day · Algeria
BOD and COD removal from town sewage by activated sludge with clarifiers and chlorination
- BOD removed
- 95%
- Suspended solids removed
- 91%
For more information, contact us
Municipal wastewater · 30,000 m³/day · Brazil
BOD and faecal coliform removal from municipal sewage by stabilisation ponds in series
- BOD removed
- 84%
- COD removed
- 74%
For more information, contact us
Municipal wastewater · 1,000,000 m³/day capacity · China
Meeting a local discharge standard for city sewage by A2O, biofilter, UF, ozone and UV
- Phosphorus removed
- 99.1%
- Ammonia removed
- 99.0%
For more information, contact us
Municipal wastewater · 7,776 m³/day · Colombia
BOD and COD removal from city sewage by UASB reactors followed by activated sludge
- BOD removed
- 95%
- Suspended solids removed
- 90%
For more information, contact us
Municipal wastewater · 35,000 m³/day capacity · Egypt
COD and BOD removal from municipal sewage by an advanced sequencing batch reactor
- Suspended solids removed
- 95%
- BOD removed
- 94%
For more information, contact us
Municipal wastewater · 21,000 m³/day · Greece
BOD and COD removal from septage and municipal sewage by primary settling and activated sludge
- Suspended solids removed
- 99.8%
- BOD removed
- 99.6%
For more information, contact us
Municipal wastewater · 13,000 m³/day · Hungary
Heavy metal fate in town sewage through grit removal, primary settling and activated sludge
- Iron removed
- 99.0%
- Manganese removed
- 50%
For more information, contact us