Aguato

    Meeting a local discharge standard for city sewage by A2O, biofilter, UF, ozone and UV

    The largest secondary sewage plant in Beijing, with a treatment scale of 1,000,000 m³/day. Its treated water meets Grade B of the city's local discharge standard for municipal plants, and sodium acetate is dosed as an extra carbon source for denitrification. Sludge goes through thermal hydrolysis, anaerobic digestion with combined heat and power, filter pressing and land application.

    Treatment line

    1. 01Modified A2O processSecondary biological treatment.
    2. 02Denitrification biofilterFurther treatment of the secondary effluent.
    3. 03Ultrafiltration
    4. 04Ozone contact reactor
    5. 05Ultraviolet disinfection

    What the source found

    The plant removed about 95% of COD and 99% of BOD, ammonia and phosphorus, and 78% of total nitrogen, meeting its local standard. Energy recovered from sludge digestion and from effluent heat almost covers the plant's energy use, but its emission cuts offset only part of its greenhouse gas emissions, with nitrous oxide the largest single source. Fully recovering heat from the secondary effluent with heat pumps could make the plant a net energy producer and a carbon sink.

    Annual average inlet and outlet quality for 2020, used with plant energy and chemical records to account for energy use and greenhouse gas emissions.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L2831595%
    BOD5BOD5mg/L1752.599%
    Total phosphorusTPmg/L6.90.05999.1%
    Total nitrogenTNmg/L50.610.979%
    Suspended solidsTSSmg/L239<5
    Colourmg/L505.489%
    Ammonium nitrogenNH4-Nmg/L44.280.4599.0%

    Inlet: raw wastewater at the plant inlet. Outlet: final effluent after ultraviolet disinfection. Annual average influent and effluent quality for 2020. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.