Aguato

    Organic matter removal from sewage by UASB reactors followed by trickling filters

    A municipal plant in Accra, Ghana, treats sewage from households, offices and commercial areas of about 100,000 inhabitants, with no known industrial discharges, and releases the effluent into a nearby lagoon. Its anaerobic reactors are built for 16,000 to 18,000 m³/day but receive an average of about 4330 m³/day. Raw sewage first passes a coarse screen, a wet well and a vortex grit removal unit, after which the section described here begins.

    Treatment line

    1. 01Fine screenFurther screening of the degritted sewage.
    2. 02Six UASB reactors in parallelEach 1300 m³, with an average hydraulic retention time of about 46 hours at about 26 °C; biogas is collected in gas hoods and flared, and excess sludge goes to thickeners and drying beds.
    3. 03Trickling filtersCircular filters with plastic media and natural air flow, without recirculation; two of the three were working during the study.
    4. 04Final settling tanksTwo circular clarifiers that settle biofilm sloughed from the filters before discharge.

    What the source found

    The plant removed 93% of COD and 98% of BOD, with most of the organic matter and solids removed in the anaerobic reactors, and the effluent met the national discharge guidelines for organic matter and indicator bacteria. Nitrogen and phosphorus were not adequately removed: phosphorus rose through the plant and nitrate increased, which was attributed to the filters lacking recirculation, too little carbon left for denitrification and the nutrient balance of the sewage. The reactors produced biogas that could be recovered for energy instead of being flared, but a large part of the methane left dissolved in the effluent.

    Composite samples of degritted raw sewage and of the effluent of each stage, taken twice a week for organics and weekly for nutrients, microbes and metals, over 35 weeks from January to August 2021.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.28.2
    Temperature°C26.224.1
    Electrical conductivityECµS/cm3,0972,977
    Dissolved oxygenDO0.293.56
    CODCODmg/L2,12215293%
    BODBODmg/L1,3843398%
    Total solidsTSmg/L2,4391,05657%
    Total suspended solidsTSSmg/L9797293%
    Total dissolved solidsTDSmg/L1,48095536%
    Total volatile solidsTVSmg/L68248.393%
    Total nitrogenTNmg/L114.4683.6127%
    Ammonia nitrogenNH3-Nmg/L67.5161.41
    Nitrate nitrogenNO3-Nmg/L7.9410.930%
    Orthophosphate as phosphorusPO4-Pmg/L19.521.15
    Total phosphorusTPmg/L25.0928.370%
    SulfateSO42−mg/L146.4682.4544%
    SulfideS2−mg/L1.320.1986%
    Faecal coliformsFCCFU/100 mL3.4 × 10^21.7 × 10^195%
    Escherichia coliCFU/100 mL2.5 × 10^21.2 × 10^195%
    SalmonellaCFU/100 mL4.7 × 10^22.7 × 10^194%
    Helminth eggsNot detectedNot detected
    ChromiumCrmg/L0.83
    NickelNimg/L0.05
    ZincZnmg/L0.009
    CadmiumCdmg/L0.157
    ManganeseMnmg/L0.009
    LeadPbmg/L0.005
    CopperCumg/L0.19
    MercuryHgµg/L0.742

    Inlet: degritted raw sewage entering the anaerobic reactors. Outlet: effluent of the final settling tanks. Averages of composite samples over 35 weeks from January to August 2021. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.

    Similar references