Irrigation-quality effluent from resort sewage by anoxic treatment and a membrane bioreactor
The plant serves the Kızkalesi neighbourhood of Erdemli district in Mersin province, a tourist resort whose population of about 1,800 in winter rises to 50,000 to 60,000 in July and August. Its nominal capacity is 1,000 m³/day for the winter population and it is designed for 7,940 m³/day in the summer peak. All treated water currently goes to a nearby stream, and its reuse for farm irrigation was assessed.
Treatment line
- 01Coarse and fine screens
- 02Sand and oil trap
- 03Balancing poolStabilises the incoming sewage.
- 04De-oxidation pool
- 05Anoxic pool
- 06Pre-aeration pool
- 07Membrane systemMembrane bioreactor stage with 5,927 m² of membrane area; the sludge it forms is returned to the process.
What the source found
The plant removed about 96% of BOD, 94% of COD and 93% of suspended solids, and total phosphorus fell by about 55%. Its effluent met the national Class A criteria for irrigation reuse and was judged suitable for agricultural irrigation, though its sodium content placed it in the third chemical quality class for that parameter.
Inlet and outlet samples were analysed in duplicate at an accredited laboratory, with the inlet values given as a summer and winter average.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.5 | 7.47 | |||
| Electrical conductivity | EC | µS/cm | 1,438 | 1,056 | |
| BOD | BOD | mg/L | 149.5 | 5.96 | 96% |
| COD | COD | mg/L | 192.5 | 11.17 | 94% |
| Coliforms | CFU/100 mL | 0 | |||
| Suspended solids | TSS | mg/L | 106 | 7.2 | 93% |
| Total phosphorus | TP | mg/L | 3.18 | 1.43 | 55% |
| Total nitrogen | TN | mg/L | 50.51 | 10.2 | 80% |
| Nitrate nitrogen | NO3-N | mg/L | 17.20 in one table, 7.20 in another | ||
| Chloride | Cl− | mg/L | 2,244 | 71.1 | |
| Active chlorine | Cl2 | mg/L | 0.35 | ||
| Total dissolved solids | TDS | mg/L | 73.3 | ||
| Sodium | Na | mg/L | 59.98 | ||
| Sodium adsorption ratio | 9.44 | ||||
| Aluminium | Al | mg/L | <0.7 | ||
| Arsenic | As | mg/L | 0.053 | 0.023 | 57% |
| Beryllium | Be | mg/L | <0.005 | ||
| Cadmium | Cd | mg/L | 0.056 | 0.0415 | 26% |
| Hexavalent chromium | Cr(VI) | mg/L | 0.058 | 0.05 | 14% |
| Cobalt | Co | mg/L | <0.005 | <0.005 | |
| Copper | Cu | mg/L | 0.0695 | 0.0625 | 10% |
| Fluoride | F− | mg/L | <0.2 | ||
| Iron | Fe | mg/L | <0.2 | ||
| Lead | Pb | mg/L | 0.3 | 0.15 | 50% |
| Lithium | Li | mg/L | 0.001 | ||
| Manganese | Mn | mg/L | <0.05 | ||
| Molybdenum | Mo | mg/L | <0.005 | ||
| Nickel | Ni | mg/L | 0.21 | 0.15 | 29% |
| Selenium | Se | mg/L | <0.005 | ||
| Vanadium | V | mg/L | 0.003 | ||
| Zinc | Zn | mg/L | 0.18 | 0.08 | 56% |
Inlet: raw sewage at the plant inlet. Outlet: treated water leaving the membrane system. Inlet values are a summer and winter average and outlet values are means of duplicate analyses; number of samples and period not stated. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.