Meeting tighter nutrient limits by multi-stage A2/O, chemical settling and sand filtration
A municipal wastewater treatment plant in Hebei Province, China, designed for 60,000 m³/day, that previously used sequencing batch reactors and took in about 41,700 m³/day. It was upgraded to meet a stricter discharge standard, because of weak nitrogen and phosphorus removal, short reactor retention and poor filtration, and it then handled a larger inflow. Treated water is discharged to a drainage channel or sent through ultrafiltration for reuse in irrigation, vehicle washing and street cleaning.
Treatment line
- 01Coarse screen and lift pumping station
- 02Fine screen
- 03Aerated grit chamber
- 04Multi-stage anaerobic, anoxic and aerobic tanksBuilt inside the old reactor tanks in two trains: anaerobic, first anoxic, first aerobic, degassing, second anoxic and second aerobic zones, the first aerobic zone being the longest at 9.6 hours, with sodium acetate added as a carbon source.
- 05Secondary sedimentation tanksHorizontal-flow tanks 4.5 m deep with chain scrapers.
- 06High-efficiency sedimentation tanksTwo sets of mixing, flocculation and inclined-tube settling with sludge return, dosed with polyaluminium ferric chloride to remove phosphorus.
- 07Filter tanksMedia changed from ceramic granules to quartz sand.
- 08Sodium hypochlorite disinfection
What the source found
After the upgrade the plant removed 95% of COD, above 99% of ammonia, 87% of total nitrogen and 98% of total phosphorus, and the effluent met the stricter standard even with a higher inflow. Electricity use per cubic metre fell, as did the use of sodium acetate, disinfectant and polymer.
Continuous online monitoring of inlet and outlet quality after the upgrade, with daily values and their average for October 2023.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 6.93 | 6.77 | |||
| COD | COD | mg·L-1 | 211.69 | 11.51 | 95% |
| Ammonia nitrogen | NH3-N | mg·L-1 | 35.93 | 0.06 | 99.8% |
| Total nitrogen | TN | mg·L-1 | 68.35 | 9.23 | 87% |
| Total phosphorus | TP | mg·L-1 | 4.42 | 0.09 | 98% |
Inlet: raw sewage at the plant inlet. Outlet: final effluent at the plant outlet. Averages of daily online monitoring values for October 2023, after the upgrade. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.