Aguato

    Shrinking the concentrate from municipal water reuse by high-recovery closed-circuit RO

    A municipal water reclamation facility ran a pilot on its tertiary effluent to see how far reverse osmosis recovery could be pushed and so shrink the concentrate stream of a purified water replenishment program. The effluent was first passed through ultrafiltration and an equalization tank; the figures here cover the closed-circuit RO stage that followed, and all pilot outflows went back to the head of the plant.

    Treatment line

    1. 01Closed-circuit reverse osmosis25 RO elements in one stage, about 929 m² of membrane, fed at about 15.9 m³/h; the concentrate is recirculated until a set point and then purged, with recovery raised step by step during the trial.

    What the source found

    At the first and lowest recovery step the RO removed 95% of dissolved solids, 93% of organic carbon, 96% of chloride, above 99% of sulfate and 80% of nitrate, with divalent ions held back better than monovalent ones. As recovery was raised further, removal of dissolved solids, alkalinity, chloride, nitrate, sodium and potassium fell, while sulfate, calcium and magnesium removal stayed steady; the ultrafiltration ahead of it removed all suspended particles.

    Samples of the RO feed, permeate and concentrate taken at each recovery step from October 2020 to May 2021, each measurement at least in triplicate, with the full set of results reported for the lowest recovery step.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH6.35.5
    Temperature°C20.919.6
    Electrical conductivityECµs/cm1,01858
    Total dissolved solidsTDSmg/L5902995%
    Total suspended solidsTSSmg/Lnot detected
    Total organic carbonTOCmg/L4.70.3593%
    Alkalinity as CaCO3Alkmg/L629.4
    TurbidityNTUnot detectednot detected
    UV254 transmittance%80.597.7
    Free chlorine residual as Cl2Cl2mg/L0.43
    Total chlorine residual as Cl2Cl2mg/L1.3
    ChlorideCl−mg/L1204.496%
    FluorideF−mg/L0.18not detected>99.9%
    Nitrate as nitrogenNO3-Nmg/L9.31.980%
    Total phosphorus as phosphateTPmg/L0.56
    Sulfate as the ionSO42−mg/L1800.599.7%
    Total silica as SiO2SiO2mg/L23
    Ammonia as nitrogenNH3-Nmg/L8.9
    Total bariumBamg/L0.036
    Total calciumCamg/L50.70.13399.7%
    Total magnesiumMgmg/L6.92not detected>99.9%
    Total manganeseMnmg/L0.0051
    Total sodiumNamg/L1107.793%
    Total potassiumKmg/L171.293%
    Total ironFemg/L0.052
    Total aluminiumAlmg/Lnot detected
    Total strontiumSrmg/L0.31
    E. coliMPN/100 mLnot detectednot detected
    Total coliformsTCMPN/100 mLnot detectednot detected

    Inlet: feed to the closed-circuit reverse osmosis stage. Outlet: reverse osmosis permeate. Samples at the 90% recovery step, each measurement at least in triplicate. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.