Aguato

    COD and oil removal from industrial estate wastewater by tube settlers and media filtration

    A common effluent treatment plant serving an industrial area in Delhi, India, discharges its treated water to a river. Designed for 12,000 m³/day, it treats about 3,500 m³/day because the connected industries changed their processes. The scheme is chemical precipitation and filtration with no biological unit; tertiary filters were included because reuse for horticulture was planned.

    Treatment line

    1. 01Preliminary treatment
    2. 02Equalisation tank8-hour retention.
    3. 03Pre-chlorination0.5-hour retention.
    4. 04Tube settlers0.25-hour retention.
    5. 05Clarified effluent sump0.5-hour retention.
    6. 06Dual media filtersMultimedia filtration as part of the tertiary stage.
    7. 07Activated carbon filterSecond part of the tertiary stage.
    8. 08Chlorination1-hour retention.

    What the source found

    COD and suspended solids were each reduced by only about 55%, and ammonia and sulphide hardly changed. Oil and grease met its discharge standard. This plant had the lowest overall efficiency of the five plants compared, which is put down to the absence of a biological unit.

    Grab samples at the plant inlet and final outlet in two campaigns between April and July 2017.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BODBODmg/Laround 762863%
    CODCODmg/L22010055%
    Total suspended solidsTSSmg/L1486655%
    pH7.38.1
    Oil and greaseO&Gmg/L24.4484%
    Ammonium nitrogenNH4-Nmg/L1614.96.9%
    Orthophosphate as phosphorusPO4-Pmg/L4.12.734%
    ChlorideCl−mg/L29020529%
    Sulfate as SO4SO42−mg/L149.3108.727%
    FluorideF−mg/L0.60.3148%
    Sulfide as SS2−mg/L7.26.94.2%
    ZincZnmg/L1.170.5553%
    CopperCumg/L2.970.0499%
    ChromiumCrmg/L0.370.2435%
    ManganeseMnmg/L0.220.1914%
    NickelNimg/L3.71.1469%
    LeadPbmg/L0.160.0569%
    CadmiumCdmg/L1.640.7356%

    Inlet: raw effluent at the plant inlet. Outlet: final treated effluent at the plant outlet. Grab samples in two campaigns between April and July 2017. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references