    COD and BOD removal from industrial estate wastewater by clariflocculation and activated sludge

    A common effluent treatment plant at an integrated industrial estate at Pantnagar in northern India discharges its treated water to a river. It was designed for 4,000 m³/day and operates at 2,100 m³/day. Before the sampled section the water passes bar screens, a raw effluent sump, a grit chamber, an oil and grease chamber and an equalisation tank, with about 20 hours retention in the last three together.

    Treatment line

    1. 01Flash mixer
    2. 02ClariflocculatorChemical settling; sludge goes to storage and drying beds.
    3. 03pH-correction tank
    4. 04Aeration tankActivated sludge, with sludge returned from the secondary clarifier.
    5. 05Secondary clarifier6.5-hour retention; surplus sludge is thickened and dried on beds.
    6. 06Two pressure sand filters0.3-hour retention.
    7. 07Treated water tank

    What the source found

    Overall the plant removed 90% of COD, 91% of BOD and 93% of suspended solids. Ammonia fell by 77% to below its discharge standard, while nitrate rose. Good sludge settling gave more satisfactory performance here than at the other plants compared.

    Grab samples from the equalisation tank, after primary settling, after the secondary clarifier and at the final outlet, in two campaigns from December to January 2020.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L4804690%
    BODBODmg/L1271191%
    Total suspended solidsTSSmg/L2692093%
    pH7.37.5
    Oil and greaseO&Gmg/L160>99.9%
    Ammonium nitrogenNH4-Nmg/L10.12.377%
    Total Kjeldahl nitrogenTKNmg/L25.32.889%
    Nitrate nitrogenNO3-Nmg/L480%
    Orthophosphate as phosphorusPO4-Pmg/L3.20.7676%
    Total phosphorusTPmg/L9.111.8879%
    ChlorideCl−mg/L621871%
    Sulfate as SO4SO42−mg/L21.4958%
    FluorideF−mg/L0.90.4946%
    Sulfide as SS2−mg/L1.80.856%

    Inlet: equalisation tank. Outlet: final outlet after sand filtration. Grab samples in two campaigns from December to January 2020. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.