Aguato

    Mixed industrial estate wastewater treatment references

    A mixed industrial estate sends the combined wastewater of many factories to one plant, so the load and what it contains change from day to day.

    References
    10
    Countries
    5
    State a flow
    8
    Removal

    What they report removing

    • COD9 references, from 55% to 96%86%Median
    • Suspended solids8 references, from 49% to 98%82%Median

    Share removed between the inlet and the outlet, counted across the references below that report each parameter. A parameter that did not fall counts as zero. Parameters reported by fewer than five references are left out.

    The references

    10 mixed industrial estate references

    Mixed industrial estate · 600 m³/day · Iran

    COD and cyanide removal from industrial estate wastewater by anaerobic reactor and lagoons

    Zinc removed
    95%
    Suspended solids removed
    92%
    For more information, contact us
    Mixed industrial estate · 2,100 m³/day · India

    COD and BOD removal from industrial estate wastewater by clariflocculation and activated sludge

    Suspended solids removed
    93%
    BOD removed
    91%
    For more information, contact us
    Mixed industrial estate · 4,500 m³/day · India

    BOD and COD removal from industrial estate effluent by MBBR, sand and carbon filtration

    Oil and grease removed
    93%
    Phosphorus removed
    65%
    For more information, contact us
    Mixed industrial estate · 2,500 m³/day · India

    COD and solids removal from electroplating estate wastewater by flocculation and tube settlers

    Oil and grease removed
    88%
    Fluoride removed
    75%
    For more information, contact us
    Mixed industrial estate · 3,500 m³/day · India

    COD and oil removal from industrial estate wastewater by tube settlers and media filtration

    Oil and grease removed
    84%
    Suspended solids removed
    55%
    For more information, contact us
    Mixed industrial estate · 4,000 m³/day capacity · Vietnam

    COD and nitrogen removal from industrial zone wastewater by coagulation and anoxic/oxic process

    COD removed
    86%
    Total nitrogen removed
    79%
    For more information, contact us
    Mixed industrial estate · 2,000 m³/day capacity · Vietnam

    COD and suspended solids removal from industrial park wastewater by sequencing batch reactor

    Suspended solids removed
    98%
    COD removed
    90%
    For more information, contact us
    Mixed industrial estate · 24,810 m³/day · Turkey

    COD and solids removal from industrial zone wastewater by chemical and biological treatment

    Suspended solids removed
    98%
    COD removed
    96%
    For more information, contact us
    Mixed industrial estate · Egypt

    COD removal from industrial estate wastewater by settling, equalization and evaporation ponds

    COD removed
    77%
    Chromium removed
    53%
    For more information, contact us
    Mixed industrial estate · Egypt

    COD and BOD removal from mixed industrial wastewater by electro-Fenton pretreatment

    COD removed
    84%
    BOD removed
    82%
    For more information, contact usLab test