    COD and BOD removal from textile mill wastewater by an undersized activated sludge plant

    A textile mill in Santa Clara, Cuba, treats an average of 3,600 m³/day of wastewater in an activated sludge plant whose design matches extended aeration. Only one aeration compartment has been in use since 2003, when the flow fell with the mill's output, and with production rising again the plant no longer meets the discharge standard for COD, which brings fines.

    Treatment line

    1. 01Activated sludge aeration tankOnly one compartment in service, with a calculated retention time of about 7.5 hours, shorter than recommended; the plant has a sludge return stream.
    2. 02First sedimentation
    3. 03Second sedimentation

    What the source found

    The line removed 76% of COD and 86% of BOD, but outlet COD was unstable and often above the discharge limit, because the retention time and sludge age were too short and no nutrients were added. Bringing two or three aeration compartments back into use would give retention times and sludge ages in the recommended range, letting the effluent meet the standard, and the investment was judged economically acceptable.

    Samples at the plant inlet and outlet from January to March 2015, extra COD analyses of the outlet in May and June, solids measured at six points along the plant, and a mass balance to recalculate the operating parameters.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH9.348.5
    Electrical conductivityECus/cm21,2351,300
    TemperatureºC3228
    Settleable solidsmg/L10.0199.0%
    BOD5BOD5mg/L25536.786%
    COD (reflux)CODmg/L42410176%
    Total nitrogenTNmg/L63297%
    Total phosphorusTPmg/L0.270.0774%
    Total suspended solidsTSSmg/L252212%
    Volatile suspended solidsVSSmg/L7140%
    Fixed suspended solidsFSSmg/L18856%
    Oil and grease (n-hexane extractables)O&Gmg/L9456%

    Inlet: raw wastewater at the plant inlet. Outlet: treated wastewater at the plant outlet. Characterisation of samples taken from January to March 2015. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.