COD and solids removal from batik wastewater by anaerobic tanks and a constructed wetland
A communal plant in use since 2017 in a village of Pekalongan City, Central Java, treating wastewater from 40 batik enterprises. It covers 500 m² and has a capacity of 250 m³/day, and the city designed it for low operating and maintenance cost to meet the provincial discharge standard for textile and batik wastewater.
Treatment line
- 01Equalization tankReceives the raw batik wastewater and also takes back water recirculated from the anaerobic stage.
- 02Anaerobic biological tanksClosed tanks where microbes convert organic matter to methane and carbon dioxide with little sludge and low energy use.
- 03Constructed wetlandA 15 by 7 m bed, 1 m deep, packed with 4 to 10 cm rocks and planted with three plant species, with water recirculated from its outlet back to its inlet.
What the source found
In this sampling the plant removed 99% of COD, 98% of suspended solids and 59% of total chromium. All seven monitored effluent parameters met the provincial standard, and an effluent quality index rated this plant the most effective of three batik plants in the city. Except for the anaerobic tanks the plant is open, so rain can cause overflow to rivers.
One sampling of the inlet and outlet in January 2019, taken from the city environmental office's monitoring data.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Temperature | °C | 38 | 28 | ||
| BOD5 | BOD5 | mg/L | 3 | 6 | 0% |
| COD | COD | mg/L | 2,505 | 33 | 99% |
| Total suspended solids | TSS | mg/L | 258 | 6 | 98% |
| Total chromium | Cr | mg/L | 0.17 | 0.07 | 59% |
| Total ammonia | NH3 | mg/L | 3.5 | 1 | 71% |
| pH | 9.7 | 7.8 |
Inlet: raw batik wastewater at the plant inlet. Outlet: constructed wetland effluent at the plant outlet. One sampling in January 2019 from the city environmental office's monitoring data. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.