Aguato

    COD and suspended solids removal from batik wastewater by activated sludge

    A communal plant in operation since 2007 in a village of Pekalongan City, Central Java, treating wastewater from 23 batik enterprises. It covers 200 m² and has a capacity of 150 m³/day. It was designed to combine chemical coagulation with biological treatment, but the chemical step was left out because treating the inorganic sludge cost too much.

    Treatment line

    1. 01Equalization and settling tankReceives the raw batik wastewater.
    2. 02Aeration tankThe activated sludge stage.
    3. 03Settling tankSludge is returned to the process and excess sludge is withdrawn.

    What the source found

    In the July 2018 round the plant removed 84% of COD and 90% of suspended solids. Its effluent met the provincial standard except for COD in that same July round. Aeration needs a lot of energy and the process produces excess sludge.

    Inlet and outlet samples from two monitoring rounds in 2018, taken from the city environmental office's data; the figures used are from the July 2018 round.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Temperature°C2828
    BOD5BOD5mg/L51982%
    CODCODmg/L1,04616484%
    Total suspended solidsTSSmg/L1952090%
    Total ammoniaNH3mg/L0.40.250%
    pH8.88

    Inlet: raw batik wastewater at the plant inlet. Outlet: settling tank effluent at the plant outlet. One monitoring round in July 2018 from the city environmental office's data. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.