Suspended solids and COD removal from batik dyeing wastewater by aluminium electrocoagulation
Batik workshops in Pekalongan, Central Java, Indonesia, produce strongly coloured wastewater that is often discharged to rivers. Concentrated first-wash wastewater from the dyeing, shaving and rinsing steps of the local batik industry was treated in a small batch electrocoagulation cell as a possible low-cost method for the area.
Treatment line
- 01Electrocoagulation cell with aluminium electrodesA 3 litre acrylic bath holding 2.5 litres of wastewater, with aluminium plates of 12 by 14 cm spaced 2 cm apart on a direct current supply, run at three voltages for 90 to 180 minutes.
What the source found
Removal rose with both voltage and contact time. At the highest voltage and longest time the cell removed 76% of COD, 84% of BOD and 94% of suspended solids; suspended solids then met the industry standard, but COD and BOD remained well above it, so further treatment would be needed before discharge.
Batch tests at three voltages and four contact times, with COD, BOD and suspended solids measured before and after each run. The removal figures are from the single run at the highest voltage and longest time.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/L | 4,161.5 | 1,007.5 | 76% |
| BOD | BOD | mg/L | 1,528.9 | 248.4 | 84% |
| Total suspended solids | TSS | mg/L | 164 | 10 | 94% |
| pH | 8.12 |
Inlet: raw dyeing wastewater before electrocoagulation. Outlet: wastewater after electrocoagulation at 30 V for 180 minutes. One batch run at 30 V for 180 minutes, compared with the initial characterisation of the same wastewater. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.