Aguato

    BOD and COD removal from septage and municipal sewage by primary settling and activated sludge

    A plant in the Attica region, operating since 1986, that treats municipal sewage from northern suburbs and is the only facility in the region that accepts septic tank sewage from unsewered areas. About 700 trucks a day deliver some 11,000 m³ of septage, alongside about 10,000 m³ per day of sewered wastewater; the design is 24,000 m³ per day of septage and 20,000 m³ per day of sewage for 500,000 inhabitants. The two streams are kept physically separate through pretreatment and primary settling, and treated water is discharged or reused on site after sand filtration.

    Treatment line

    1. 01Screens25 mm and 10 mm openings, shared by both streams.
    2. 02Aerated grit chamber300 m³ with three blowers, shared by both streams.
    3. 03Ferrous sulphate and lime dosingSeptage stream only: ferrous sulphate removes sulphide and lime improves flocculation.
    4. 04Primary sedimentation tanksSeparate per stream: two covered circular tanks of 2,700 m³ in total for septage, two rectangular tanks for sewage.
    5. 05Aeration tank21,000 m³ with 15 surface aerators and 6 submersible mixers.
    6. 06Secondary sedimentation tanksTwo circular tanks of 4,570 m³ each; sludge is returned to the aeration tank and the excess goes to digestion.
    7. 07Chlorination basin1,600 m³ in four channels, dosed with sodium hypochlorite before discharge or reuse.

    What the source found

    Despite variations in the inflow, the plant removed 99% of COD, above 99% of BOD and suspended solids, 84% of total nitrogen and 85% of total phosphorus in 2023, and complied fully with the EU urban wastewater limits in both years studied. Energy use stayed stable at about 0.6 kWh per m³, in the lower quartile of comparable plants, with aeration taking about half of it.

    Annual averages from the national monitoring database for 2023, from 149 inlet samplings and 148 to 251 outlet samplings per parameter, set against daily energy use.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Total nitrogenTNmg/L10616.784%
    Total phosphorusTPmg/L172.685%
    BOD5BOD5mg/L1,122.34.799.6%
    CODCODmg/L2,594.425.299.0%
    Total suspended solidsTSSmg/L1,421.23.599.8%

    Inlet: raw septage and sewage at the plant inlet. Outlet: treated water at the plant outlet. Annual averages for 2023 from 149 inlet and 148 to 251 outlet samplings per parameter. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.