Aguato

    BOD and solids removal at a buffalo abattoir by air flotation and a sequencing batch reactor

    A buffalo abattoir at Kairana, Shamli district, Uttar Pradesh, has capacity to slaughter 600 buffalo a day, for a production of 72 tonnes a day of frozen meat and poultry feed supplement and 8 tonnes a day of tallow. Its effluent treatment plant is designed for 500 m³/day and treated on average 254 m³/day while it was monitored. Treated water is used for gardening and irrigation.

    Treatment line

    1. 01Screen chamber13.8 m³.
    2. 02Oil and grease removal tank18 m³.
    3. 03Equalisation tank103 m³, mixed by diffused air.
    4. 04Dissolved air flotation25.4 m³ unit where coagulant and compressed air are mixed into the wastewater to float out fat and solids.
    5. 05Sequencing batch reactorOne 1,404 m³ aerated activated sludge tank for BOD removal.
    6. 06Treated water and disinfection tank405 m³.
    7. 07Multi-media filter2.26 m³.
    8. 08Activated carbon filter2.26 m³.
    9. 09Final treated water tank130.8 m³.

    What the source found

    The plant removed 96% of COD, 98% of BOD, 99% of suspended solids, 73% of oil and grease and 85% of ammonium nitrogen, and performed well for carbon and nitrogen removal, though ammonium remained high in the final outlet. The wastewater was short of phosphorus for the biology, and the sand and carbon filters polished less than intended, which points to lower filtration rates.

    Replicate samples from the inlet, the stages of the plant and the final outlet were analysed in a university laboratory, with on-site checks of the aeration tank sludge.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH6.537.47
    TurbidityNTU638.122.7796%
    AlkalinityAlkmg/L253.33143.33
    Oil and greaseO&Gmg/L9.772.673%
    BODBODmg/L1,304.3325.6798%
    CODCODmg/L2,760103.6796%
    Total suspended solidsTSSmg/L2,500.332399.1%
    Ammonium nitrogenNH4-Nmg/L361.6753.8785%
    Nitrate nitrogenNO3-Nmg/L0.67.430%
    Orthophosphate as phosphorusPO4-Pmg/L5.070.93

    Inlet: raw wastewater at the treatment plant inlet. Outlet: final treated effluent. Averages of replicate samples analysed in a university laboratory. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.