Nitrogen removal from city sewage by step-feed anoxic and aerobic activated sludge
An underground municipal sewage works in downtown Taipei, treating on average 433,820 m³ per day and built below ground because of the lack of land, with a recreation and education centre on top. It was designed to remove both organic matter and nitrogen, and its sewage has a high ratio of COD to nitrogen.
Treatment line
- 01Step-feed anoxic and aerobic tanksThree feed points to three anoxic tanks and three large aeration tanks, each large tank divided into four smaller ones; about 4.5 hours of total retention and a sludge age of about 7 days.
What the source found
The works removed solids, COD and BOD well, with about 89% COD and 92% BOD removal, but removed nitrogen and phosphorus less well: total nitrogen removal was about 58% and ammonia removal 59%. There was enough carbon for denitrification, but the oxygen level in the anoxic tanks was too high for complete nitrogen removal.
Monthly influent and effluent samples over one year in 2018 to 2019, 12 samples in all, together with sludge samples for microbial analysis.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Temperature | °C | 25.2 | 25.1 | ||
| pH | 7.0 to 7.2 | 6.9 to 7.1 | |||
| Suspended solids | TSS | mg L-1 | 127 | 14 | 89% |
| BOD | BOD | mg L-1 | 126 | 10 | 92% |
| COD | COD | mg L-1 | 275 | 30 | 89% |
| Ammonium nitrogen | NH4-N | mg L-1 | 21 | 8.6 | 59% |
| Nitrate nitrogen | NO3-N | mg L-1 | 0.2 | 0.5 | 0% |
| Nitrite nitrogen | NO2-N | mg L-1 | 0.04 | 0.02 | 50% |
| Organic nitrogen | mg L-1 | 4.2 | 1.5 | ||
| Total Kjeldahl nitrogen | TKN | mg L-1 | 25.2 | 10.1 | 60% |
| Total nitrogen | TN | mg L-1 | 25.4 | 10.6 | 58% |
| Total phosphorus | TP | mg L-1 | 2.9 | 1.5 | 48% |
Inlet: plant influent. Outlet: plant effluent. Means of 12 monthly samples over one year in 2018 and 2019. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.