COD and solids removal from brewery wastewater by UASB reactor and post-aeration
A large brewery in Kilinto, Addis Ababa, Ethiopia, treats its wastewater in an on-site plant designed for 1550 m³ per day before discharging it to a river, where local farmers also take the water for irrigation. Each unit of the operating plant was assessed, along with whether the treated water suits irrigation.
Treatment line
- 01Influent tankReceives the raw wastewater with a retention time of about 5 minutes.
- 02Static fine screenMechanical pre-treatment to limit the suspended solids reaching the UASB reactor.
- 03Equalization tankAbout 8 hours of retention to level out flow peaks, acidity and organic load, with partial acidification.
- 04UASB reactorAnaerobic sludge blanket that breaks down organic matter and produces biogas.
- 05Post-aeration tankAerates the anaerobic effluent to remove odour and further organic matter; the effluent is decanted and settled sludge returned to the basin.
What the source found
The plant removed 97% of COD and 96% of suspended solids, with most of the COD removed in the UASB reactor. Nutrient removal was weak, about 58% of total nitrogen and 49% of total phosphorus, and the phosphorus leaving the plant stayed above the national discharge limit. Better nutrient removal and online monitoring were recommended.
Composite samples taken three times a day, in triplicate, after each unit from January to April 2024, plus grab samples from the final effluent auto sampler.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Temperature | °C | 29.37 | 25.35 | ||
| pH | 9.3 | 7.5 | |||
| COD | COD | mg/L | 4,928.1 | 136.2 | 97% |
| BOD5 | BOD5 | mg/L | 3,409.5 | 38.34 | 99% |
| Total suspended solids | TSS | mg/L | 757.1 | 32.3 | 96% |
| Total phosphorus | TP | mg/L | 33.2 | 16.8 | 49% |
| Total nitrogen | TN | mg/L | 39.9 | 16.9 | 58% |
| Dissolved oxygen | DO | mg/L | 0.22 | 4.2 | |
| Electrical conductivity | EC | μS/cm | 2,459.1 | 285.1 | |
| Ammonium nitrogen | NH4-N | mg/L | 0.82 | 0.39 | 52% |
| Volatile fatty acids | VFA | mg/L | 1,132.8 | 64.1 | 94% |
| Turbidity | NTU | 1,134 | 323.9 | 71% | |
| Total coliforms | TC | CFU/100 ml | 14,279.17 | ||
| E. coli | CFU/100 ml | 4,491.67 |
Inlet: raw brewery wastewater in the influent tank. Outlet: treated effluent tank after post-aeration. Means of composite samples taken three times a day, in triplicate, January to April 2024; the two bacteria counts are averages given in the text for the effluent only. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.