    COD and nitrogen polishing of UASB-treated brewery effluent by two constructed wetlands

    A brewery in Kombolcha, northern Ethiopia, already treats its wastewater in a full-scale UASB reactor of 592 m³ taking about 840 m³ per day, after screens and a buffering tank. The UASB effluent still carried too much organic matter, solids and nutrients for the national discharge standard, so a pilot two-stage horizontal subsurface flow wetland was built on the brewery site and fed 0.698 m³ per day of that effluent. Only the wetland stage is described here.

    Treatment line

    1. 01Distribution tankA 3000 L tank stores UASB effluent and feeds the wetland through a gate valve.
    2. 02First horizontal subsurface flow wetland cellConcrete cell of 7.56 m by 1.52 m filled 0.45 m deep with clay rock media and planted with Cyperus alternifolius.
    3. 03Second horizontal subsurface flow wetland cellSame size and media as the first cell, planted with Typha latifolia; the two cells give about 4 days of retention.
    4. 04Collection tankReceives the treated water from the second cell.

    What the source found

    Over the year the two cells together removed on average 92% of COD, 89% of suspended solids, 84% of total nitrogen, 93% of ammonium nitrogen and 74% of total phosphorus. The treated water met the national discharge limits for solids, COD and nitrogen all year, but phosphorus exceeded its limit in most months after August, probably because the clay media became saturated.

    Samples three times a month for one year at the UASB outlet (wetland inlet), between the two cells and at the outlet of the second cell, reported as monthly means; the removal figures shown are the October means.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    Total suspended solidsTSSmgL-1211.422.889%
    CODCODmgL-143642.890%
    Total nitrogenTNmgL-148.67.485%
    Ammonium nitrogenNH4-NmgL-135.73.291%
    Total phosphorusTPmgL-123.29.460%
    OrthophosphatePO43−mgL-119.65.771%

    Inlet: anaerobic reactor effluent entering the first wetland cell. Outlet: outlet of the second wetland cell. October monthly means of samples taken three times a month. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.