UF suppliers for pretreatment, reuse, and potable water, hollow-fiber and spiral-wound membrane systems at any scale.

    Find a Ultrafiltration System Provider

    Matched providers: 112

    Top countries: China, United States

    Popular technologies: Reverse Osmosis (RO), Ultrafiltration (UF)

    Ultrafiltration Membrane Systems: Module Design, Integrity Testing, and Fouling Control

    Ultrafiltration (UF) membranes (pore size 0.01 to 0.1 micron, MWCO 10,000 to 150,000 Dalton) remove suspended solids, bacteria, viruses (partially), Cryptosporidium, Giardia, and macromolecular organics by size exclusion. Transmembrane pressure (TMP) for UF: 0.1 to 1.0 bar (10 to 100 kPa) vs RO at 5 to 80 bar; low-energy process. UF module configurations: hollow-fibre (HF, outside-in or inside-out flow; fibres 0.5 to 2 mm inner diameter, 1 to 2 million fibres per module, offered by the major membrane manufacturers); spiral-wound (less common for UF, used in NF/RO); multi-tubular (large-bore, 5 to 25 mm, for high-turbidity or high-fouling feeds). Hollow fibre outside-in (feed on shell side, permeate inside fibres): standard for drinking water; better solids handling, backwashable; inside-out (feed inside fibres, permeate on shell side): higher pressure, used in some wastewater applications. Flux rates: 40 to 100 LMH (L/m2/h) for drinking water UF at 0.2 to 0.5 bar TMP; 20 to 60 LMH for wastewater secondary effluent polishing; higher flux increases fouling rate.

    UF system design includes backwash, forward flush, and chemical enhanced backwash (CEB) cycles to maintain membrane performance. Standard cycle: filtration 20 to 60 minutes, backwash 30 to 60 seconds (permeate at 1.5 to 3 times flux rate in reverse); air-assisted backwash (air scouring at 0.1 to 0.3 bar) for outside-in modules. CEB (chemical enhanced backwash): periodic backwash with low-dose chemical (chlorine 50 to 200 mg/L for organic fouling; caustic NaOH pH 12 for biofouling; citric acid 0.2 percent for inorganic scaling) every 1 to 12 hours depending on source water quality.

    CIP (clean-in-place): more intensive chemical cleaning (chlorine 500 to 2,000 mg/L, NaOH 1 percent, citric acid 2 percent) conducted when TMP reaches 1.5 to 2 times initial value; frequency varies from weekly to monthly depending on water quality. Fouling types: reversible (hydraulic backwash restores flux); irreversible reversible (CEB restores); irreversible (CIP required); truly irreversible (membrane replaced). UF membrane life: 5 to 10 years typically; integrity failure (fibre breach from mechanical fatigue, oxidant damage) reduces earlier; minimise hypochlorite exposure (limit CEB chlorine dose and frequency to protect PVDF fibre from oxidative damage).

    UF in drinking water treatment: standalone UF or as pre-treatment to NF/RO. Standalone drinking water UF: pre-coagulation (alum or ferric, 1 to 10 mg/L inline dose) before UF removes NOM and colloidal silica that would foul UF and does not pass size exclusion; UF provides Cryptosporidium log removal credit (greater than 4 log per US EPA LT2ESWTR; 3 to 4 log per UK DWI guidance); post-UF disinfection (chlorination + UV at 40 mJ/cm2) provides additional multi-barrier. UF before RO: seawater RO UF pre-treatment reduces SDI15 from greater than 5 to less than 2, improving RO performance and extending membrane life; replaces conventional sand filtration + coagulation with more compact, consistent process. Wastewater UF applications: membrane bioreactor (MBR) integrates UF with biological treatment (activated sludge at MLSS 6,000 to 15,000 mg/L); HF UF submerged in aeration tank or external sidestream; treats sewage to effluent quality suitable for direct reuse (SS less than 1 mg/L, BOD5 less than 5 mg/L, E. coli less than 1 cfu/100 mL); no secondary clarifier required. Leading MBR suppliers include the established membrane manufacturers.

    Frequently Asked Questions

    What is the difference between microfiltration and ultrafiltration?

    Microfiltration (MF) and ultrafiltration (UF) are both low-pressure membrane processes but differ in pore size and removal capability: MF: pore size 0.1 to 1.0 micron; MWCO not applicable (pores too large for molecular weight characterisation); removes: suspended solids, bacteria (greater than 6 log), Cryptosporidium (4 to 6 micron, greater than 4 log), Giardia (8 to 12 micron, greater than 4 log); does NOT remove viruses reliably (20 to 300 nm, smaller than MF pores, limited log removal 1 to 2 log at best); does NOT remove macromolecular organics (NOM, humic acids). UF: pore size 0.01 to 0.1 micron; MWCO 10,000 to 150,000 Da; removes all MF targets PLUS: viruses (1 to 3 log for larger viruses; greater than 3 log for tight UF less than 100,000 MWCO); macromolecular organics (greater than 100,000 Da) partially. Practical distinctions: UF provides higher treatment security for virus removal; MF is lower TMP (0.05 to 0.3 bar) and lower cost per membrane area; both provide Cryptosporidium barrier. US EPA LT2ESWTR awards both MF and UF the same Cryptosporidium log removal credit (up to 5.5 log) based on integrity testing demonstration rather than pore size.

    How is UF membrane integrity tested?

    UF membrane integrity testing detects fiber breaches or defects that could allow pathogens to bypass the membrane barrier. Standard method: Pressure Decay Test (PDT, also called Pressure Hold Test or Air Pressure Test): (1) Drain permeate side of membrane; (2) Apply air pressure at 20 to 40 kPa (2 to 4 times typical TMP) to feed side or permeate side; (3) Monitor pressure decay over 5 to 15 minutes; (4) Calculate rate of pressure decay (kPa/min); (5) Compare to integrity threshold corresponding to required log removal credit (US EPA IT/CR relationship: lower decay rate = higher log removal credit); integrity failure indicated by decay rate greater than threshold. Alternative methods: Direct Turbidity Test (DTT): online turbidity monitoring of permeate (greater than 0.15 NTU indicates potential integrity breach). Diffusive Air Flow (DAF) test: measures airflow through wetted membrane pores at given transmembrane pressure - flow increases with fiber breach. PDT sensitivity limits: can detect a single broken fiber in a module (smallest detectable breach 3 to 4 log Cryptosporidium equivalent); US EPA IT/CR guidance (2005, updated) provides calculation methodology. Frequency: US LT2ESWTR requires continuous online turbidity monitoring plus periodic PDT (minimum every 2 days for full credit). UK DWI: PDT or equivalent required at frequency specified in plant's risk assessment; typically daily or after each CIP.

    What causes UF membrane fouling and how is it controlled?

    UF membrane fouling types and control: (1) Organic fouling (NOM, humic acids, EPS from algae/bacteria): most common in surface water UF; forms gel layer on membrane surface; controlled by: pre-coagulation (alum 1 to 5 mg/L inline removes NOM adsorbed on coagulant floc); CEB with NaOH (pH 11 to 12, 2 to 4 minutes) breaks down organic gel layer; reduce flux (lower TMP); (2) Biofouling (bacterial biofilm on membrane surface): controlled by: chlorine CEB (50 to 200 mg/L, 2 to 5 minutes) kills biofilm-forming bacteria; minimise biofilm-forming NOM in feed; UV pre-disinfection; maintain minimum chlorine residual in feed; (3) Inorganic scaling (calcium carbonate, iron, manganese, silica): controlled by: acid CEB (citric acid 0.2 to 0.5 percent, or HCl pH 2 to 3); pre-treatment to remove iron/manganese (oxidation-filtration, green sand); reduce feed calcium and bicarbonate (softening); (4) Colloidal fouling (clay, fine silica): controlled by: pre-coagulation; backwash optimisation (air + water); reduce feed turbidity via pre-settling. Typical fouling indicator: TMP rise rate (kPa/hour at constant flux); design target less than 0.1 kPa/hour. Fouling prevention hierarchy: reduce feed loading, optimise backwash, CEB, CIP as escalating interventions.

    What is the energy consumption of ultrafiltration systems?

    UF system energy consumption depends on configuration, flux rate, and pre/post-treatment: Pressure-driven UF (feed pumped through external pressure vessel modules): energy 0.05 to 0.15 kWh/m3 for drinking water at 40 to 60 LMH, TMP 0.2 to 0.5 bar; add pre-treatment (coagulation dosing) and post-treatment (UV, chlorination) for total system energy 0.1 to 0.3 kWh/m3 for standalone surface water UF plant. Submerged UF (gravity or low-suction, permeate drawn by vacuum from hollow fibres submerged in tank): energy 0.1 to 0.2 kWh/m3; aeration for scouring adds 0.05 to 0.1 kWh/m3; lower pressure than external but higher air energy. MBR (UF integrated with biological treatment): total energy 0.4 to 1.0 kWh/m3 wastewater treated (higher aeration demand for MLSS 8,000 to 15,000 mg/L); aerobic MBR 0.6 to 1.0 kWh/m3; anoxic/anaerobic zone reduces aeration. Comparison: RO desalination 2.5 to 4.0 kWh/m3; conventional surface water treatment 0.1 to 0.3 kWh/m3; UF is comparable to or slightly more than conventional for drinking water applications. Energy efficiency improvements: VFD pump control; flux optimisation (reduce flux to reduce TMP and fouling-related CIP chemical and downtime costs); energy recovery from backwash water.

    Aguato
    • Find projects
    • Insider
    • NeptiAI
    Home/Directory/Treatment Technologies

    Ultrafiltration System Companies

    UF suppliers for pretreatment, reuse, and potable water, hollow-fiber and spiral-wound membrane systems at any scale.

    111 specialist providers · 1 related · 22 countries

    Post a project

    Qualified suppliers come to you.

    Filter results

    Country

    China31
    United States19
    Spain11
    Italy10
    Germany7

    Industry

    Utilities83
    Manufacturing76
    Waste Management and Remediation56
    Construction and Real Estate29
    Chemicals and Pharmaceuticals26

    Technology

    Reverse Osmosis (RO)56
    Ultrafiltration (UF)51
    Filtration39
    Ion Exchange34
    Nanofiltration (NF)25

    Not sure where to start?

    Showing 1-20 of 112

    Specialists in ultrafiltration system

    Providers whose services or self-declared specialties match this category.

    HIDRO-WATER S.L.U

    Spain · 51-200 employees

    Hidro-Water S.L.U specializes in the manufacturing and provision of advanced water treatment equipment. Based in Spain, they offer solutions for residential, industrial, and municipal applications, focusing on technologies like reverse osmosis, ultrafiltration, and greywater recycling to enhance water quality and sustainability.

    Reverse Osmosis (RO)Ultrafiltration (UF)Industrial WWTPs

    Lenntech B.V.

    Netherlands · 51-200 employees

    Lenntech B.V. specializes in providing tailor-made water treatment solutions, offering a range of services including reverse osmosis, ultrafiltration, and containerized systems. Operating primarily in Europe, they cater to industries such as food and beverage, utilities, and manufacturing, ensuring efficient water reuse and treatment.

    Reverse Osmosis (RO)Ultrafiltration (UF)Industrial Water Reuse

    Zyramic, Inc.

    Verified

    United States

    Zyramic manufactures membrane modules for membrane bioreactors, ultrafiltration and microfiltration. The company supplies modules rather than complete treatment systems, and works alongside the integrators and contractors who deliver the rest of the train. The polymer line is the Zyramic Palisade flat sheet cassette, a submerged PES flat sheet module for municipal and industrial MBR duty. A detachable scour manifold gives every plate its own dedicated scour air, continuously, so channels stay open and operators stay out of the tank. Published preliminary design basis covers 130 plate and 260 plate cassettes, roughly 136 to 273 m2 of membrane area, on a 304 stainless frame. The ceramic line covers silicon carbide and alumina elements in flat sheet and tubular form, for streams that need backwashing, aggressive cleaning chemistry, oil tolerance or very long module life. Modules are cut, welded, assembled and packed at the company's own factory in Poughkeepsie, New York. Cassettes are available for purchase or for rental where a plant needs a pilot or temporary capacity, and the factory also cuts replacement flat sheet plates for plants running cassettes from other suppliers. Field services are available.

    Membrane Bioreactors (MBR)Flat Sheet UF MembranesCeramic UF Membrane Systems

    Chemipol S.A.

    Spain · 51-200 employees

    Chemipol S.A. is a leading manufacturer and supplier of biocides, additives, and specialty chemicals, serving diverse industries such as utilities, manufacturing, and energy production. Based in Spain, Chemipol provides advanced water treatment solutions, including desalination and wastewater treatment technologies, across Europe.

    Reverse Osmosis (RO)Ultrafiltration (UF)Microfiltration (MF)
    SH

    Shenzhen Hidly Water Purification Technology Co., Ltd.

    China · 51-200 employees

    Shenzhen Hidly Water Purification Technology Co., Ltd. specializes in manufacturing advanced water purification equipment and providing cutting-edge technology solutions across China and the Asia-Pacific region. The company focuses on delivering high-quality treatment solutions and infrastructure systems for various industries.

    Reverse Osmosis (RO)Ultrafiltration (UF)Point-of-Use (POU) Filters

    Hikins (Jiangsu) Envirotech Co., Ltd.

    China · 200+ employees

    Hikins (Jiangsu) Envirotech Co., Ltd. is a leading manufacturer of water treatment components, specializing in advanced filtration and purification technologies. Serving the construction, manufacturing, and utilities sectors, Hikins provides innovative solutions for water treatment plants and systems across China and the Asia-Pacific region.

    Reverse Osmosis (RO)Ultrafiltration (UF)Microfiltration (MF)

    Hainan Litree Purifying Technology Co., Ltd.

    China · 200+ employees

    Hainan Litree Purifying Technology Co., Ltd. is a leading Chinese manufacturer specializing in ultrafiltration membrane technology. The company provides advanced water purification and treatment solutions for residential, commercial, and industrial applications, serving diverse industries including utilities and manufacturing.

    Ultrafiltration (UF)Reverse Osmosis (RO)Nanofiltration (NF)

    PolyCera, a brand of PSP.US, Inc.

    United States · 51-200 employees

    PolyCera® membrane products, a PSP.US, Inc. brand, set new standards in performance and total cost of ownership, aiming to deliver the highest quality of treatment with unrivaled reliability at the lowest total lifetime cost through the reduction of OpEx and CapEx. With current installed capacity exceeding 50 MGD, PolyCera membranes have been used in a wide range of projects including: Clean Energy, Fossil Fuel Energy, Industrial Wastewater, Process Separation and Municipal Water and Wastewater. Show more

    Ultrafiltration (UF)Nanofiltration (NF)Industrial Water Reuse

    Cimico

    Spain · 51-200 employees

    Cimico specializes in innovative biological wastewater technologies, providing advanced solutions for industrial and municipal water treatment. With a focus on sustainable practices, Cimico serves diverse industries across Europe, offering expertise in treatment solutions, water reuse, and infrastructure systems.

    Industrial WWTPsMunicipal WWTPsActivated Carbon Filtration

    Yuyao Ruiao Water Purification Equipment Co., Ltd.

    China · 51-200 employees

    Yuyao Ruiao Water Purification Equipment Co., Ltd. specializes in manufacturing advanced water purification equipment, serving industries such as construction, manufacturing, and utilities. Based in China, the company provides solutions like reverse osmosis and ultrafiltration for effective water treatment and infrastructure development.

    Reverse Osmosis (RO)Ultrafiltration (UF)Industrial WWTPs

    Hidrofilt Ltd.

    Hungary · 51-200 employees

    Hidrofilt Ltd. is a leading designer, manufacturer, and operator in water treatment solutions, specializing in filtration technologies and wastewater treatment plants. Serving diverse industries, it provides comprehensive services from design to maintenance, ensuring efficient and sustainable water management across Europe.

    Reverse Osmosis (RO)Ultrafiltration (UF)Industrial WWTPs

    Ecosystems International

    Verified

    Indonesia · 51-200 employees

    PT Ecosystems International (PT ESI) was established at Jakarta on 21st November 2006. We are an industrial effluent treatment systems integrator specializing in electrocoagulation (EC), a unique waste water treatment profile. PT ESI has capabilities in designing complete waste water treatment solutions by combining various effluent treatment systems such as the electro-coagulation, biological, chemical processes and membrane filtration, offering its customers a wide and comprehensive range of solutions, tailored to suit their various needs – ranging from basic effluent treatment for discharge to effluent recycling for water reuse. The Company is experienced in handling the design, engineering, procurement, construction and operation of new Effluent Treatment Plants (“ETP”) and possesses expertise in retrofitting existing ETP to increase the flow rate and treatment capability without any major infrastructure increase PT ESI is also a premier waste water treatment service company specializing in handling waste water generated from Exploration (Drilling) and Produced Water. Customers in Indonesia include major Oil & Gas companies such as Pertamina, Exxon, Chevron, Petro-China and Medco. Operations in Indonesia are provided by both mobile and fixed units. At drill sites where waste-water recycling is required, PT ESI supplement these treatment units with skid mounted mobile Reverse Osmosis systems. The technologies and solutions employed by PT ESI are developed in-house and examples of these are its proprietary Trident™ Electro Contaminant Removal (“ECR”) system, the Stage Contaminant Removal (“SCR”) process and Mobile On-Site Waste-Water Treatment (“OWT”) units

    Reverse Osmosis (RO) SystemsUltrafiltration (UF) SystemsMulti-media Filtration (MMF) Systems

    American Water Chemicals (AWC®)

    United States · 51-200 employees

    American Water Chemicals (AWC®) specializes in chemical and technical solutions for optimizing membrane systems, including RO, NF, MF, and UF. With over 30 years of expertise, AWC® offers a comprehensive range of antiscalants, cleaning chemicals, and biocides, supported by advanced software for precise scaling projections.

    Reverse Osmosis (RO)Ultrafiltration (UF)Nanofiltration (NF)

    Brine Consulting

    Verified

    Netherlands · 1-50 employees

    BRINE CONSULTING delivers senior-level strategy, technical design, and actionable insight across the full lifecycle of water-related challenges. We support clients with advisory and due diligence, advanced brine management and resource recovery, industrial and municipal water reuse, and MLD/ZLD systems. Our team also leads ESG and climate-resilience strategy, innovation scouting, and international development and PPP advisory. With deep specialization in desalination, brine valorization, circular economy models, and high-impact infrastructure, we help organizations turn water and waste streams into opportunities, providing clear thinking, rapid delivery, and solutions built for real-world results.

    Activated Carbon FiltrationReverse Osmosis (RO) SystemsUltrafiltration (UF) Systems

    Haining BEISHI Environment Protection Technology CO., LTD

    China · 200+ employees

    Haining BEISHI Environment Protection Technology CO., LTD is a leading innovator in water pre-treatment systems, offering advanced filtration solutions and a wide range of water purification products. With a strong presence in China and the Asia-Pacific region, the company serves the utilities and manufacturing industries, providing high-quality equipment and technology.

    Point-of-Use (POU) FiltersReverse Osmosis (RO)Ultrafiltration (UF)
    NR

    Ningbo RXHL Technology Co., Ltd.

    China · 200+ employees

    Ningbo RXHL Technology Co., Ltd. is a leading high-tech enterprise in China, specializing in the research, production, and sales of advanced membrane materials and components. With a focus on microfiltration, ultrafiltration, nanofiltration, and reverse osmosis technologies, the company serves diverse industries including food and beverage, petrochemicals, and municipal water treatment.

    Reverse Osmosis (RO)Ultrafiltration (UF)Microfiltration (MF)

    LG Chem / LG Water Solutions

    South Korea · 200+ employees

    LG Water Solutions, a division of LG Chem, is a global leader in advanced water treatment technologies. They offer a comprehensive portfolio of solutions, including reverse osmosis membranes, ion exchange resins, and ultrafiltration membranes, to address water scarcity and quality challenges across municipal, industrial, and commercial sectors.

    Reverse Osmosis (RO)Ultrafiltration (UF)Nanofiltration (NF)
    SL

    Shandong LoyalMem Tech Co., Ltd.

    Verified

    China · 51-200 employees

    Shandong LoyalMem Tech Co., Ltd. manufactures reverse osmosis (RO), ultrafiltration (UF), nanofiltration (NF) and membrane bioreactor (MBR) membrane products, along with electrodeionization (EDI) modules, for industrial and municipal water-treatment applications. LoyalMem supplies membrane elements and modules for water-treatment equipment manufacturers, engineering companies and project buyers.

    Reverse OsmosisUltrafiltrationNanofiltration
    GE

    GTE ELETTROMECCANICA

    Italy · 51-200 employees

    GTE ELETTROMECCANICA specializes in providing advanced water treatment solutions, including equipment manufacturing and technology provision for utilities and industrial applications. Based in Italy, the company serves the European market with a focus on desalination, ultra-pure water systems, and membrane technologies.

    Reverse Osmosis (RO)Ultrafiltration (UF)Industrial WWTPs

    ENERGY ENERAGUA S.L.L.

    Spain · 1-50 employees

    Eneragua specializes in the design, manufacture, and installation of water treatment systems, with a focus on reverse osmosis and ultrafiltration. With over 30 years of experience, they offer comprehensive solutions for water purification, maintenance, and technical support, ensuring efficient and sustainable water management.

    Reverse Osmosis (RO)Ultrafiltration (UF)Plant Operation Services
    • Previous
    • 1
    • 2
    • 3
    • 4
    • More pages
    • 6
    • Next

    Buyer's guide

    The buyer's guide to ultrafiltration system

    OverviewFAQScenarioQuestions to askCost driversRegulations

    Ultrafiltration Membrane Systems: Module Design, Integrity Testing, and Fouling Control

    Ultrafiltration (UF) membranes (pore size 0.01 to 0.1 micron, MWCO 10,000 to 150,000 Dalton) remove suspended solids, bacteria, viruses (partially), Cryptosporidium, Giardia, and macromolecular organics by size exclusion. Transmembrane pressure (TMP) for UF: 0.1 to 1.0 bar (10 to 100 kPa) vs RO at 5 to 80 bar; low-energy process. UF module configurations: hollow-fibre (HF, outside-in or inside-out flow; fibres 0.5 to 2 mm inner diameter, 1 to 2 million fibres per module, offered by the major membrane manufacturers); spiral-wound (less common for UF, used in NF/RO); multi-tubular (large-bore, 5 to 25 mm, for high-turbidity or high-fouling feeds). Hollow fibre outside-in (feed on shell side, permeate inside fibres): standard for drinking water; better solids handling, backwashable; inside-out (feed inside fibres, permeate on shell side): higher pressure, used in some wastewater applications. Flux rates: 40 to 100 LMH (L/m2/h) for drinking water UF at 0.2 to 0.5 bar TMP; 20 to 60 LMH for wastewater secondary effluent polishing; higher flux increases fouling rate.

    UF system design includes backwash, forward flush, and chemical enhanced backwash (CEB) cycles to maintain membrane performance. Standard cycle: filtration 20 to 60 minutes, backwash 30 to 60 seconds (permeate at 1.5 to 3 times flux rate in reverse); air-assisted backwash (air scouring at 0.1 to 0.3 bar) for outside-in modules. CEB (chemical enhanced backwash): periodic backwash with low-dose chemical (chlorine 50 to 200 mg/L for organic fouling; caustic NaOH pH 12 for biofouling; citric acid 0.2 percent for inorganic scaling) every 1 to 12 hours depending on source water quality.

    CIP (clean-in-place): more intensive chemical cleaning (chlorine 500 to 2,000 mg/L, NaOH 1 percent, citric acid 2 percent) conducted when TMP reaches 1.5 to 2 times initial value; frequency varies from weekly to monthly depending on water quality. Fouling types: reversible (hydraulic backwash restores flux); irreversible reversible (CEB restores); irreversible (CIP required); truly irreversible (membrane replaced). UF membrane life: 5 to 10 years typically; integrity failure (fibre breach from mechanical fatigue, oxidant damage) reduces earlier; minimise hypochlorite exposure (limit CEB chlorine dose and frequency to protect PVDF fibre from oxidative damage).

    UF in drinking water treatment: standalone UF or as pre-treatment to NF/RO. Standalone drinking water UF: pre-coagulation (alum or ferric, 1 to 10 mg/L inline dose) before UF removes NOM and colloidal silica that would foul UF and does not pass size exclusion; UF provides Cryptosporidium log removal credit (greater than 4 log per US EPA LT2ESWTR; 3 to 4 log per UK DWI guidance); post-UF disinfection (chlorination + UV at 40 mJ/cm2) provides additional multi-barrier. UF before RO: seawater RO UF pre-treatment reduces SDI15 from greater than 5 to less than 2, improving RO performance and extending membrane life; replaces conventional sand filtration + coagulation with more compact, consistent process. Wastewater UF applications: membrane bioreactor (MBR) integrates UF with biological treatment (activated sludge at MLSS 6,000 to 15,000 mg/L); HF UF submerged in aeration tank or external sidestream; treats sewage to effluent quality suitable for direct reuse (SS less than 1 mg/L, BOD5 less than 5 mg/L, E. coli less than 1 cfu/100 mL); no secondary clarifier required. Leading MBR suppliers include the established membrane manufacturers.

    Post your ultrafiltration system project

    Frequently asked questions

    What is the difference between microfiltration and ultrafiltration?

    Microfiltration (MF) and ultrafiltration (UF) are both low-pressure membrane processes but differ in pore size and removal capability: MF: pore size 0.1 to 1.0 micron; MWCO not applicable (pores too large for molecular weight characterisation); removes: suspended solids, bacteria (greater than 6 log), Cryptosporidium (4 to 6 micron, greater than 4 log), Giardia (8 to 12 micron, greater than 4 log); does NOT remove viruses reliably (20 to 300 nm, smaller than MF pores, limited log removal 1 to 2 log at best); does NOT remove macromolecular organics (NOM, humic acids). UF: pore size 0.01 to 0.1 micron; MWCO 10,000 to 150,000 Da; removes all MF targets PLUS: viruses (1 to 3 log for larger viruses; greater than 3 log for tight UF less than 100,000 MWCO); macromolecular organics (greater than 100,000 Da) partially. Practical distinctions: UF provides higher treatment security for virus removal; MF is lower TMP (0.05 to 0.3 bar) and lower cost per membrane area; both provide Cryptosporidium barrier. US EPA LT2ESWTR awards both MF and UF the same Cryptosporidium log removal credit (up to 5.5 log) based on integrity testing demonstration rather than pore size.

    How is UF membrane integrity tested?

    UF membrane integrity testing detects fiber breaches or defects that could allow pathogens to bypass the membrane barrier. Standard method: Pressure Decay Test (PDT, also called Pressure Hold Test or Air Pressure Test): (1) Drain permeate side of membrane; (2) Apply air pressure at 20 to 40 kPa (2 to 4 times typical TMP) to feed side or permeate side; (3) Monitor pressure decay over 5 to 15 minutes; (4) Calculate rate of pressure decay (kPa/min); (5) Compare to integrity threshold corresponding to required log removal credit (US EPA IT/CR relationship: lower decay rate = higher log removal credit); integrity failure indicated by decay rate greater than threshold. Alternative methods: Direct Turbidity Test (DTT): online turbidity monitoring of permeate (greater than 0.15 NTU indicates potential integrity breach). Diffusive Air Flow (DAF) test: measures airflow through wetted membrane pores at given transmembrane pressure - flow increases with fiber breach. PDT sensitivity limits: can detect a single broken fiber in a module (smallest detectable breach 3 to 4 log Cryptosporidium equivalent); US EPA IT/CR guidance (2005, updated) provides calculation methodology. Frequency: US LT2ESWTR requires continuous online turbidity monitoring plus periodic PDT (minimum every 2 days for full credit). UK DWI: PDT or equivalent required at frequency specified in plant's risk assessment; typically daily or after each CIP.

    What causes UF membrane fouling and how is it controlled?

    UF membrane fouling types and control: (1) Organic fouling (NOM, humic acids, EPS from algae/bacteria): most common in surface water UF; forms gel layer on membrane surface; controlled by: pre-coagulation (alum 1 to 5 mg/L inline removes NOM adsorbed on coagulant floc); CEB with NaOH (pH 11 to 12, 2 to 4 minutes) breaks down organic gel layer; reduce flux (lower TMP); (2) Biofouling (bacterial biofilm on membrane surface): controlled by: chlorine CEB (50 to 200 mg/L, 2 to 5 minutes) kills biofilm-forming bacteria; minimise biofilm-forming NOM in feed; UV pre-disinfection; maintain minimum chlorine residual in feed; (3) Inorganic scaling (calcium carbonate, iron, manganese, silica): controlled by: acid CEB (citric acid 0.2 to 0.5 percent, or HCl pH 2 to 3); pre-treatment to remove iron/manganese (oxidation-filtration, green sand); reduce feed calcium and bicarbonate (softening); (4) Colloidal fouling (clay, fine silica): controlled by: pre-coagulation; backwash optimisation (air + water); reduce feed turbidity via pre-settling. Typical fouling indicator: TMP rise rate (kPa/hour at constant flux); design target less than 0.1 kPa/hour. Fouling prevention hierarchy: reduce feed loading, optimise backwash, CEB, CIP as escalating interventions.

    What is the energy consumption of ultrafiltration systems?

    UF system energy consumption depends on configuration, flux rate, and pre/post-treatment: Pressure-driven UF (feed pumped through external pressure vessel modules): energy 0.05 to 0.15 kWh/m3 for drinking water at 40 to 60 LMH, TMP 0.2 to 0.5 bar; add pre-treatment (coagulation dosing) and post-treatment (UV, chlorination) for total system energy 0.1 to 0.3 kWh/m3 for standalone surface water UF plant. Submerged UF (gravity or low-suction, permeate drawn by vacuum from hollow fibres submerged in tank): energy 0.1 to 0.2 kWh/m3; aeration for scouring adds 0.05 to 0.1 kWh/m3; lower pressure than external but higher air energy. MBR (UF integrated with biological treatment): total energy 0.4 to 1.0 kWh/m3 wastewater treated (higher aeration demand for MLSS 8,000 to 15,000 mg/L); aerobic MBR 0.6 to 1.0 kWh/m3; anoxic/anaerobic zone reduces aeration. Comparison: RO desalination 2.5 to 4.0 kWh/m3; conventional surface water treatment 0.1 to 0.3 kWh/m3; UF is comparable to or slightly more than conventional for drinking water applications. Energy efficiency improvements: VFD pump control; flux optimisation (reduce flux to reduce TMP and fouling-related CIP chemical and downtime costs); energy recovery from backwash water.

    Illustrative scenario · Drinking water treatment and membrane technology

    A composite drawn from typical projects in this category, not a single client engagement. Figures are indicative.

    Challenge
    A water company in South East England abstracting from a lowland river with highly variable turbidity (5 to 450 NTU) and elevated NOM (TOC 8 to 14 mg/L) needed to increase treatment capacity from 12 MLD to 28 MLD at an existing works with a constrained site footprint. Conventional settlement expansion was not feasible within the site boundary.
    Approach
    The engineer specified pressure-driven outside-in UF membranes (0.02 micron PVDF hollow fibre) with coagulant-enhanced pre-treatment (PACl at 4 to 8 mg/L inline) to address NOM fouling. The system was designed for 50 LMH operating flux with automatic backwash every 30 minutes and chemical-enhanced backwash (CEB) twice weekly using NaOCl (500 mg/L). Integrity testing by pressure hold test was specified at 30-minute intervals. Permeate UVT averaged 92%, enabling downstream UV dosing at 40 mJ/cm2.
    Outcome
    The UF system consistently achieved permeate turbidity below 0.05 NTU even during peak raw water turbidity events of 420 NTU, providing 4 log Cryptosporidium reduction credit per the DWI risk assessment. System energy consumption averaged 0.11 kWh/m3 at design flux. Membrane integrity (SDI15 below 0.5 on all trains) was maintained throughout the first 18 months of operation. CIP chemical consumption was 30% below design estimate due to optimised CEB scheduling.

    Questions to ask shortlisted providers

    5
    1. 01

      What is the target membrane flux (LMH), and has the design flux been validated against the specific raw water fouling potential (SDI, SUVA, TOC)?

      Operating above the critical flux for the specific water quality causes irreversible fouling; SUVA (specific UV absorbance) above 2.5 L/mg.m indicates high NOM fouling risk requiring lower flux or inline coagulation pre-treatment.

    2. 02

      What Cryptosporidium log reduction credit will be assigned to the UF system under the DWI risk assessment, and what integrity testing frequency is required?

      DWI Cryptosporidium risk assessments assign log credit to UF based on demonstrated integrity testing; pressure hold test or vacuum decay test must detect a single fibre break; testing frequency and alarm action levels must be defined in the risk assessment.

    3. 03

      What chemical enhanced backwash (CEB) and clean-in-place (CIP) frequency and chemical regime is specified, and what is the wastewater disposal route?

      CEB (sodium hypochlorite and citric acid) is essential for sustainable NOM fouling management; CIP frequency affects membrane life and chemical cost; CEB/CIP reject water disposal must be accounted for in the wastewater management plan.

    4. 04

      What is the UV transmittance (UVT) of the UF permeate and does this support the downstream UV disinfection dose calculation?

      UV dose is calculated as UV intensity times exposure time at the minimum UVT; lower UVT requires higher UV intensity (more lamps, higher energy) to achieve the same log reduction; UF typically improves UVT from raw water values, reducing UV system capital and operating cost.

    5. 05

      What is the membrane warranty period and what are the manufacturer's guaranteed performance specifications for recovery, flux, and rejection?

      Membrane warranties (typically 2 to 5 years) specify minimum recovery and pressure conditions; operating outside warranty conditions voids coverage; procurement contracts should include performance guarantees linked to the warranty to protect the operator.

    What drives cost in this category

    4
    Membrane module cost and replacement frequency
    Pressure-driven UF modules cost GBP 200 to 600 per m2 of membrane area; for a 10 MLD plant at 50 LMH flux requiring approximately 200 m2 of membrane, module cost is GBP 40,000 to 120,000; typical module life 7 to 12 years with correct CEB and CIP management.
    Inline coagulant pre-treatment for NOM-rich surface water
    PACl inline coagulant pre-treatment at 4 to 8 mg/L costs GBP 0.006 to 0.018 per m3; this cost is offset by reduced membrane fouling, extended CIP intervals, and longer membrane life; omitting pre-treatment for high-NOM water causes membrane biofouling within 12 to 24 months.
    CEB and CIP chemical costs and waste disposal
    Sodium hypochlorite for CEB at 500 mg/L, 15 minutes, twice weekly: approximately GBP 0.005 to 0.015 per m3 product; citric acid CIP costs GBP 0.008 to 0.02 per m3; CEB/CIP reject water disposal to inlet works or WwTW must account for chemical oxygen demand loading.
    Automated integrity testing and SCADA monitoring
    Pressure hold or vacuum decay testing requires automated instrumentation; automatic isolation and alarm on integrity failure adds GBP 15,000 to 40,000 per system but is mandatory under DWI Cryptosporidium Risk Assessment requirements for membrane systems claiming log reduction credit.

    Key regulations and standards

    4
    DWI Cryptosporidium in Water Supplies Regulations 1999 and UF Log Credit
    UF membranes with pore size below 0.2 micron can be assigned Cryptosporidium log reduction credit in the DWI risk assessment; credit is conditional on continuous integrity monitoring, defined action levels, and documented testing protocol; full 4 log credit requires demonstrating breach detection below a single broken fibre.
    Water Supply (Water Quality) Regulations 2016 Turbidity Standard
    UF permeate typically achieves below 0.1 NTU, providing substantial margin against the 1 NTU parametric value; turbidimeters must be calibrated and records maintained per DWI guidance on Treatment Works Risk Assessment.
    WRAS and DWI Regulation 31 for UF Membrane Materials
    PVDF, PES, and PTFE hollow fibre membranes must be manufactured from DWI Approved or WRAS-approved materials for potable water applications; membrane manufacturers must provide material certificates and compliance documentation.
    Environmental Permitting Regulations 2016 for Membrane Reject Disposal
    UF backwash water and CIP chemical waste must be managed under an Environmental Permit or appropriate Regulatory Position Statement; discharge to sewer requires trade effluent consent covering pH, chlorine, and BOD parameters from CIP chemicals.

    From the Insider

    • Ceramic vs Polymeric Membranes: Industrial Selection Guide
    • Graphene-Based Water Filtration: Current State and Applications
    • Reverse Osmosis Systems: Industrial Design, Sizing, and Operation
    • Ceramic Membranes: The 15-Year TCO Case Against Polymeric UF
    • Ultrafiltration Systems: A Technical Guide for Industrial Applications
    • Dialysis Water Treatment: Standards, Systems & Risks

    Explore Related Categories

    Membrane Technologies

    Reverse Osmosis System CompaniesNanofiltration System CompaniesMicrofiltration System CompaniesMembrane Filtration Companies

    Process Applications

    Membrane Bioreactor (MBR) CompaniesDrinking Water Treatment CompaniesHigh Purity Water Treatment Companies

    Common Challenges

    Turbidity Removal CompaniesPathogen Removal & Disinfection CompaniesMicroplastics Removal CompaniesPFAS Removal Water Treatment Companies
    Aguato

    The operational layer for the water industry.

    Connecting industrial buyers with water and wastewater specialists. Aguato is the ecosystem. Nepti is the intelligence engine.

    Clients

    • Post a project
    • Browse providers
    • Browse by category
    • How it works
    • Talk to us

    Providers

    • Browse projects

    Intelligence

    • Nepti
    • Nepti Design
    • Nepti Diagnose

    Company

    • About
    • Team
    • How it works
    • Insider
    • Thirsty Planet
    • The Element Book
    • Water calculators
    • Get in touch
    © 2026 Aguato·All rights reserved
    TermsPrivacyNepti