Aguato

    Domestic wastewater treatment references

    Domestic wastewater from one site, such as a campus, a hotel or a factory's staff buildings, is sewage whose flow and strength follow the hours the site is in use.

    References
    9
    Countries
    7
    State a flow
    2
    Removal

    What they report removing

    • COD9 references, from 2.1% to 92%78%Median
    • BOD8 references, from 50% to 93%86%Median

    Share removed between the inlet and the outlet, counted across the references below that report each parameter. A parameter that did not fall counts as zero. Parameters reported by fewer than five references are left out.

    The references

    9 domestic wastewater references

    Domestic wastewater · 0.9 m³/day · Lithuania

    Ammonium and phosphate polishing of household sewage effluent by zeolite and oxide-coated sand

    Ammonia removed
    86%
    Nitrate removed
    46%
    For more information, contact usPilot
    Domestic wastewater · 35 m³/day capacity · Nepal

    BOD and COD removal from campus sewage by septic tank, horizontal and vertical flow reed beds

    COD removed
    85%
    BOD removed
    84%
    For more information, contact us
    Domestic wastewater · Brazil

    COD and turbidity removal from shopping mall sewage by a membrane bioreactor

    Turbidity removed
    97%
    Colour removed
    91%
    For more information, contact usLab test
    Domestic wastewater · Ethiopia

    BOD and nitrogen removal from university campus sewage by waste stabilization ponds

    Total nitrogen removed
    79%
    BOD removed
    75%
    For more information, contact us
    Domestic wastewater · Indonesia

    BOD and COD removal from hotel wastewater by anaerobic, aerobic and wetland units

    BOD removed
    92%
    COD removed
    92%
    For more information, contact us
    Domestic wastewater · Colombia

    COD and BOD removal from university campus sewage by primary and secondary treatment

    BOD removed
    93%
    COD removed
    92%
    For more information, contact us
    Domestic wastewater · Indonesia

    BOD and suspended solids removal from domestic wastewater by anaerobic reactors and a wetland

    BOD removed
    89%
    Suspended solids removed
    86%
    For more information, contact us
    Domestic wastewater · Indonesia

    Sanitary wastewater BOD and COD removal by anaerobic baffled and moving bed biofilm reactors

    BOD removed
    76%
    COD removed
    68%
    For more information, contact us
    Domestic wastewater · Nigeria

    BOD and COD removal from power-station sewage by anaerobic and activated sludge stages

    COD removed
    54%
    BOD removed
    50%
    For more information, contact us