COD and BOD removal from university campus sewage by primary and secondary treatment
One of two treatment plants on a university campus southeast of Pereira, next to the sports facilities, needed because the city has no municipal sewage treatment. In 2017 it discharged 16,447 m³ of treated water to a local brook, and its sludge goes to improve farm soils.
Treatment line
- 01Primary treatment
- 02Secondary treatmentNo tertiary treatment follows.
What the source found
The plant removed about 92% of COD and 93% of BOD. Phosphorus is treated as not removed, and the assessment counts the effluent as having the same eutrophication potential as untreated sewage. After garden irrigation, the effluent was the largest direct contributor to the campus water scarcity footprint.
Average inlet and outlet values from characterization campaigns of the plant's wastewater, used as input to a life cycle model of the campus water footprint.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| BOD5 | BOD5 | g/m3 | 460.5 | 31.8 | 93% |
| COD | COD | g/m3 | 971 | 78.8 | 92% |
| Total phosphorus | TP | g/m3 | 11.8 | 8.7 | |
| Orthophosphate | PO43− | g/m3 | 9.5 | 6.1 | |
| Nitrate | NO3− | g/m3 | 4.5 | 3.4 | 24% |
| Nitrite | NO2− | g/m3 | 0 | 6.6 | |
| Ammoniacal nitrogen | NH3-N | g/m3 | 105 | 83.2 | 21% |
| Total Kjeldahl nitrogen | TKN | g/m3 | 146.5 | 107.5 |
Inlet: raw wastewater at the plant inlet. Outlet: treated effluent after secondary treatment. Average values from the plant characterization campaigns. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.