Aguato

    COD and turbidity removal from shopping mall sewage by a membrane bioreactor

    A bench membrane bioreactor was fed with raw sewage taken from the drain of a medium-size shopping mall with shops, a bank branch, toilets and a food court of seven restaurants and snack bars. The sewage was collected before any treatment and was stronger than ordinary domestic sewage. Malls generally discharge their treated water to the public sewer.

    Treatment line

    1. 01Buffer tankHolds the collected sewage, which a peristaltic pump feeds to the reactor.
    2. 02Submerged membrane bioreactor6 litre aerated reactor with a hollow-fibre ultrafiltration module of 0.22 m², run at a constant 40 kPa suction with 4 h permeation and 30 s backwash cycles, a sludge age of 30 days and a mean hydraulic retention time of about 4 h.

    What the source found

    The reactor removed 90% of COD, 88% of BOD, 91% of colour and 97% of turbidity, and its permeate stayed stable even though the raw sewage varied widely. Ammonium fell by 81% and phosphorus by 49%, but nitrate and nitrite rose because the cycle had no anoxic phase for denitrification. Membrane fouling was reversible and was controlled by backwashing.

    Continuous operation for 60 days in August and September, with raw sewage and permeate analysed over the period and averaged.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    ColourHazen580.151.0591%
    TurbidityNTU680.11997%
    CODCODmg L-11,849.9189.4490%
    BOD5BOD5mg L-1991.67121.2288%
    Total phosphorusTPmg L-125.312.8549%
    Total Kjeldahl nitrogenTKNmg L-132.65.0285%
    Ammonium nitrogenNH4-Nmg L-115.152.9281%
    NitriteNO2−mg L-10.651.65
    NitrateNO3−mg L-11.514.640%

    Inlet: raw mall sewage from the drain. Outlet: membrane permeate. Means over 60 days of operation in August and September. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.