Aguato

    BOD and COD removal from hotel wastewater by anaerobic, aerobic and wetland units

    An operating biological treatment plant at a hotel treats its domestic wastewater from bathrooms, washing, ablution and catering. Catering adds food waste and dish soap, which makes the feed stronger in organic matter, oil and grease and detergent, and more acidic, than domestic wastewater without catering.

    Treatment line

    1. 01Anaerobic unitFirst biological stage, with a circulation pump; most of the organic matter is broken down here.
    2. 02Aerobic unitAerated by two blowers running around the clock; its sludge is circulated, with no excess sludge, and the plant has a clarifier circulation pump.
    3. 03WetlandLast unit, with its own circulation pump.

    What the source found

    The plant removed 92% of BOD and 92% of COD, more than an anaerobic and wetland plant assessed alongside it, and its effluent met the required standard. The aerobic stage needs more equipment, control and electricity, and the line's carbon emissions are higher, mostly from anaerobic breakdown of organic matter and from the blowers.

    Inlet and outlet samples of the plant were analysed, and operation, maintenance and carbon emissions were assessed alongside.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BOD5BOD5184.314.5292%
    CODCOD267.322.1292%
    Total suspended solidsTSS681282%
    Oil and greaseO&G20.213.9980%
    Total coliformsTC18,0000>99.9%
    Surfactants (MBAS)1.8450.21189%
    pH5.77.1

    Inlet: wastewater at the plant inlet. Outlet: treated water at the plant outlet. Inlet and outlet samples of the plant analysed for the study; the source does not give the number of samples or the date. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references