Rubber wastewater treatment references
Rubber processing wastewater is acidic and strong in organic matter, ammonia and sulphate.
- References
- 8
- Countries
- 2
- State a flow
- 7
Removal
What they report removing
- Ammonia8 references, from 73% to 96%89%Median
- COD8 references, from 98% to 99.5%99.2%Median
- Total nitrogen8 references, from 73% to 95%88%Median
- BOD7 references, from 99.0% to 99.5%99.3%Median
- Suspended solids7 references, from 87% to 96%92%Median
Share removed between the inlet and the outlet, counted across the references below that report each parameter. A parameter that did not fall counts as zero. Parameters reported by fewer than five references are left out.
The references
8 rubber references
Rubber · 500 m³/day · Vietnam
COD and BOD removal from 500 m³/day of latex wastewater by decantation and oxidation ditch
- BOD removed
- 99.5%
- COD removed
- 98%
For more information, contact us
Rubber · 550 m³/day · Vietnam
COD and BOD removal from latex wastewater by decantation, flotation and oxidation ditch
- COD removed
- 99.5%
- BOD removed
- 99.4%
For more information, contact us
Rubber · 300 m³/day · Vietnam
COD and BOD removal from concentrated latex wastewater by decantation and oxidation ditch
- BOD removed
- 99.1%
- COD removed
- 98%
For more information, contact us
Rubber · 700 m³/day · Vietnam
COD and BOD removal from 700 m³/day of latex wastewater by decantation and oxidation ditch
- BOD removed
- 99.3%
- COD removed
- 99%
For more information, contact us
Rubber · 400 m³/day · Vietnam
COD and BOD removal from latex wastewater by decantation, flotation, UASB and aeration tank
- BOD removed
- 99.2%
- COD removed
- 99.1%
For more information, contact us
Rubber · 450 m³/day · Vietnam
COD and BOD removal from concentrated latex wastewater by UASB and aeration tank
- BOD removed
- 99.5%
- COD removed
- 99.3%
For more information, contact us
Rubber · 300 m³/day · Vietnam
COD and BOD removal from concentrated latex wastewater by decantation and oxidation ditch
- COD removed
- 99.3%
- BOD removed
- 99.0%
For more information, contact us
Rubber · Sri Lanka
COD and nitrogen removal from latex wastewater by anaerobic and aerobic membrane bioreactors
- COD removed
- 99.5%
- Ammonia removed
- 73%
For more information, contact usLab test