COD and BOD removal from latex wastewater by decantation, flotation, UASB and aeration tank
A natural rubber factory in the South East region of Vietnam that produces concentrated latex. Its treatment line takes on average 400 m³/day of concentrated latex wastewater, which is rich in uncoagulated rubber particles, organic matter and nitrogen.
Treatment line
- 01Decantation tankRemoves the remaining latex from the wastewater.
- 02Flotation
- 03UASB
- 04Aeration tank
- 05Settling and filter
What the source found
Removal was 99% for COD, 99% for BOD, 94% for suspended solids, 96% for ammonia and 88% for total nitrogen. The treated water still exceeded the national category B discharge limits for BOD and total nitrogen, and even more so the stricter category A limits that now apply. Nitrogen removal by the conventional biological lines used in the region was judged incomplete.
Average inlet and outlet values analysed at the factory during November 2011.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 8.09 | 7.88 | |||
| COD | COD | mg/L | 13,981 | 127 | 99.1% |
| BOD | BOD | mg/L | 7,590 | 61 | 99.2% |
| Total suspended solids | TSS | mg/L | 468 | 30 | 94% |
| Total nitrogen | TN | mg/L | 972 | 120 | 88% |
| Ammonia (NH3) | NH3 | mg/L | 686 | 30.3 | 96% |
Inlet: raw latex processing wastewater at the treatment inlet. Outlet: treated effluent at the plant outlet. Average values analysed at the factory during November 2011. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.