Aguato

    COD and BOD removal from 700 m³/day of latex wastewater by decantation and oxidation ditch

    A natural rubber factory in the South East region of Vietnam that produces concentrated latex. Its treatment line takes on average 700 m³/day of concentrated latex wastewater, which is rich in uncoagulated rubber particles, organic matter and nitrogen. The site also generates about 1,000 m³/day of other wastewater from miscellaneous latex and block rubber.

    Treatment line

    1. 01Decantation tankRemoves the remaining latex from the wastewater.
    2. 02Oxidation ditch
    3. 03Settling and filter

    What the source found

    Removal was 99% for COD, 99% for BOD, 92% for suspended solids, 95% for ammonia and 95% for total nitrogen. The treated water still exceeded the national category B discharge limits for BOD, total nitrogen and ammonia, and even more so the stricter category A limits that now apply. Nitrogen removal by the conventional biological lines used in the region was judged incomplete.

    Average inlet and outlet values analysed at the factory during November 2011.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH8.566.59
    CODCODmg/L11,93513099%
    BODBODmg/L8,7806099.3%
    Total suspended solidsTSSmg/L1,1649492%
    Total nitrogenTNmg/L1,3066795%
    Ammonia (NH3)NH3mg/L1,0435095%

    Inlet: raw latex processing wastewater at the treatment inlet. Outlet: treated effluent at the plant outlet. Average values analysed at the factory during November 2011. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.