Aguato

    Meeting a tighter COD limit for dyeing wastewater by rapid Fenton oxidation in pipe reactors

    A central treatment plant in a dyeing and finishing industry cluster in southeast China takes wastewater from more than one hundred mills, with a capacity of 400,000 m³/day. Upstream units are primary sedimentation, hydrolytic acidification, an anoxic/oxic oxidation ditch and secondary sedimentation; because biological treatment alone rarely meets the national COD limit for this sector, a rapid Fenton stage was added in 2014. The figures cover the Fenton stage itself, which is followed by shallow air flotation.

    Treatment line

    1. 01Pipeline Fenton reactor16 pipeline systems, each for 25,000 m³/day, where acidified ferrous sulphate and then hydrogen peroxide are dosed into the secondary effluent for about 24 seconds of reaction in 6.9 m³.
    2. 02NeutralisationLiquid alkali is added to stop the reaction.
    3. 03Flocculant dosingPolyacrylamide is added in the pipe to form flocs before the flow enters the flotation tank.

    What the source found

    The Fenton stage removed 45% of COD, enough to meet the national discharge limit, and 73% of phosphorus. All conventional parameters met the national standard except total nitrogen, which would need further biological treatment, and toxicity to luminescent bacteria fell. The pipeline reactors were built beneath the existing flotation unit with no extra land and were easier and cheaper to build and run than a conventional tank-based Fenton process, with similar chemical and sludge costs.

    Averages of at least triplicate samples from the running plant. The figures compare the secondary settler outlet with the Fenton line after flocculant dosing; the flotation outlet was also sampled. Stopped-flow and beaker tests on dyes and on the real secondary effluent came first.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L1407745%
    Soluble CODsCODmg/L1107136%
    Dissolved organic carbonDOCmg-C/L352626%
    BOD5BOD5mg/L3167%
    Total nitrogenTNmg-N/L48472.1%
    Ammonia nitrogenNH3-Nmg-N/L0.040.0325%
    Total phosphorusTPmg-P/L4.191.1473%
    Inhibitory effect on luminescent bacteria%513139%

    Inlet: outlet of the secondary settler. Outlet: Fenton line after flocculant dosing. Averages with standard deviations of at least triplicate samples from the running full-scale plant. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references