    Colour and turbidity removal from textile laundry effluent by alum coagulation and flocculation

    A textile laundry in Caruaru, Pernambuco, Brazil, washes and dyes about one tonne of fabric a day and uses on average 1,500 m³ of well water a month. Its treatment plant screens the wastewater and holds it in an equalisation tank before chemical treatment; the coagulation and flocculation tank has three outlets, the top one returned to the laundry for reuse, the middle one discharged to a watercourse and the bottom one sent through a brick, sand and gravel filter before discharge.

    Treatment line

    1. 01Coagulation and flocculation tankAluminium sulphate is added as coagulant and a polymer for flocculation; the middle outlet is discharged to the watercourse.

    What the source found

    The chemical stage removed 46% of COD, 46% of apparent colour and 65% of turbidity but did not lower BOD, so the discharged water became relatively more biodegradable. The COD reduction falls short of the state requirement for textile plants, so a further treatment step is needed before discharge.

    Samples were taken from the equalisation tank and from the middle outlet of the coagulation and flocculation tank and analysed in triplicate.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.37.9
    Apparent colouruH57831046%
    Electrical conductivityECµS5,6908,640
    TurbidityNTU25890.865%
    CODCODmg/L1,151.662346%
    BODBODmg/L2802800%
    Total solidsTSmg/L3,5165,4680%
    Total fixed solidsTFSmg/L73048833%
    Total volatile solidsTVSmg/L2,7864,9800%
    Total suspended solidsTSSmg/L2203485%
    Fixed suspended solidsFSSmg/L1081685%
    Volatile suspended solidsVSSmg/L1121884%
    Total dissolved solidsTDSmg/L3,3224,4200%
    Fixed dissolved solidsFDSmg/L61016673%
    Volatile dissolved solidsVDSmg/L2,7124,2540%
    Settleable solidsmL/L18478%

    Inlet: equalisation tank. Outlet: middle outlet of the coagulation and flocculation tank, discharged to the watercourse. Samples of the two streams analysed in triplicate; the figures are the means, and for the solids the mean of the two closest values. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.