    COD and BOD removal from pig farm wastewater by anaerobic digester and stabilisation lagoons

    A small full-cycle farm with 2,200 pigs in a temperate zone, where the discharges of the production stages are mixed. The line is an anaerobic digester that treats the liquid and the solids together, followed by two stabilisation lagoons in series.

    Treatment line

    1. 01Anaerobic digester for liquids and solidsTakes the raw mixed wastewater with its solids.
    2. 02Two stabilisation lagoons in series

    What the source found

    Over the whole line, COD fell by 99%, BOD by above 99%, suspended solids by 94% and phosphorus by 72%, with most of the removal in the digester and a smaller further drop in solids and organic matter in the lagoons. Kjeldahl nitrogen fell by only about a quarter over the line. The final water still did not meet the national rules because of its nitrogen and faecal coliforms.

    One grab sample each of the raw wastewater, the digester outlet and the lagoon outlet.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L7,92272.399.1%
    BOD5BOD5mg/L5,3302899.5%
    Total suspended solidsTSSmg/L3,269.23184.294%
    Volatile suspended solidsVSSmg/L2,980.77184.294%
    AlkalinityAlkmg CaCO3/L2,331882
    Total Kjeldahl nitrogenTKNmg/L1,01874827%
    Ammonium nitrogenNH4-Nmg/L496
    Nitrite plus nitrate nitrogenmg/L0.130.450%
    Total phosphorusTPmg/L101.5628.6872%
    pH7.088.29
    Faecal coliformsFCNMP/100mL130,000,00049,000>99.9%

    Inlet: raw wastewater before the anaerobic digester. Outlet: outlet of the second stabilisation lagoon. One grab sample at each point. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.