COD and heavy metal removal from pig farm wastewater by biodigester, lagoons and SBR
A farm in Yucatan state with capacity to produce 25,000 fattening pigs a year in two production modules, over a karst aquifer that is easily polluted. The treated water irrigates citrus trees, pasture and vegetables.
Treatment line
- 01Collection pits and pumping stationsOne for each of the two production modules.
- 02Drum filterA vacuum drum filter that removes biosolids.
- 03Anaerobic biodigester
- 04Two lagoons in series
- 05Homogenizing tank
- 06Two parallel sequencing batch reactorsAerated reactors.
- 07Ozone disinfection tank
What the source found
Over the whole line, COD fell by 96%, suspended solids by 96%, copper by 95%, zinc by 92%, chromium by 83% and nickel by 61%. Mercury was detected in the raw wastewater and after the biodigester on this farm, which was linked to its pig numbers and to a drum filter with too little capacity. Metals met the national discharge limits, but suspended solids and COD in the irrigation water stayed well above them.
Daily composite samples on three days of the week, three per point, of the raw wastewater in the collection tank, the water after the biodigester and the water sent to irrigation.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.01 | 8.17 | |||
| Arsenic | As | mg/L | <0.01 | <0.01 | |
| Cadmium | Cd | mg/L | <0.002 | <0.002 | |
| Copper | Cu | mg/L | 13 | 0.66 | 95% |
| Chromium | Cr | mg/L | 0.04 | 0.007 | 83% |
| Nickel | Ni | mg/L | 0.14 | 0.054 | 61% |
| Lead | Pb | mg/L | 0.004 | <0.005 | |
| Zinc | Zn | mg/L | 15 | 1.14 | 92% |
| Mercury | Hg | mg/L | 0.0025 | <0.0004 | 40% |
| Settleable solids | mg/L | 267 | 19.1 | 93% | |
| Total suspended solids | TSS | mg/L | 8,667 | 342 | 96% |
| COD | COD | mg/L | 19,578 | 871 | 96% |
Inlet: raw wastewater in the collection tank. Outlet: water sent to irrigation. Means of three daily composite samples per point, taken on three days of the week. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.