    COD and heavy metal removal from pig farm wastewater by screw separator, digester and lagoons

    A farm in Yucatan state with capacity to produce 12,300 fattening pigs a year, over a karst aquifer that is easily polluted; wastewater from the staff restrooms also goes to the plant. The treated water is used for agricultural irrigation on the farm.

    Treatment line

    1. 01Homogenizing sump
    2. 02Screw separatorReduces solids.
    3. 03Anaerobic biodigester
    4. 04Three lagoons in seriesAlso serve as the disinfection stage, with hypochlorite tablets.

    What the source found

    Over the whole line, COD fell by 96%, suspended solids by 99%, copper by 98%, zinc by 97%, chromium by 83% and nickel by 64%. Metals met the national discharge limits, but suspended solids and COD in the irrigation water stayed well above them. Copper and zinc built up strongly in the irrigated soil compared with natural soil on this farm, one of the two with the simplest treatment.

    Daily composite samples on three days of the week, three per point, of the raw wastewater in the collection tank, the water after the biodigester and the water sent to irrigation.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH6.748.11
    ArsenicAsmg/L<0.01<0.01
    CadmiumCdmg/L<0.002<0.002
    CopperCumg/L250.6198%
    ChromiumCrmg/L0.060.0183%
    NickelNimg/L0.250.0964%
    LeadPbmg/L0.051<0.005
    ZincZnmg/L180.5497%
    MercuryHgmg/L<0.0004<0.0004
    Settleable solidsmg/L7670.3>99.9%
    Total suspended solidsTSSmg/L19,76717899.1%
    CODCODmg/L30,2181,07097%

    Inlet: raw wastewater in the collection tank. Outlet: water sent to irrigation. Means of three daily composite samples per point, taken on three days of the week. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.