    Nickel and copper removal from plating wastewater by hydroxide and trithiocarbonate dosing

    Acidic mixed wastewater from an electroplating plant that runs chrome, copper, nickel and lead plating, collected as a daily composite of hourly samples. It was treated in 500 mL laboratory batches to compare metal precipitants and to test how readily the metals leach back out of the resulting sludge.

    Treatment line

    1. 01Lime dosingA lime suspension brings the acidic water to near neutral.
    2. 02Caustic soda dosingMakes the water alkaline to precipitate metal hydroxides.
    3. 03Sodium trithiocarbonate precipitationAdded until a drop test showed no further precipitate, with a slight excess, and sulfuric acid added to correct the alkalinity.
    4. 04FlocculationAn anionic flocculant is added after precipitation; ferric chloride is also used as coagulant.
    5. 05Sedimentation30 minutes of settling, after which the sludge is dewatered on filter cloth.

    What the source found

    With trithiocarbonate after hydroxide precipitation the line removed above 99% of copper, nickel and chromium, and all precipitant combinations performed similarly except the triazine reagent, which left more metal in the water. Chloride rose because of the ferric chloride. The trithiocarbonate sludge released a large share of its cadmium in leaching tests, and the sludge made with dimethyldithiocarbamate held its metals best.

    Laboratory batch tests on one daily composite sample, comparing the conventional hydroxide treatment with three sulfur-based precipitants, followed by water leaching of the dried sludge for 1 to 21 days.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH2.59.3
    Colourmg Pt/L22< 10
    TurbidityNTU210< 10
    ChlorideCl−mg/L9501,690
    SulphateSO42−mg/L1,3001,2801.5%
    CODCODmg O2/L54533039%
    Total organic carbonTOCmg/L1807558%
    Ammonium nitrogenNH4-Nmg/L151127%
    Total nitrogenTNmg/L653546%
    Total phosphorusTPmg/L7.50.593%
    CobaltComg/L1.50.00599.7%
    Hexavalent chromiumCr(VI)mg/L< 0.02< 0.02
    Total chromiumCrmg/L620.0699.9%
    CopperCumg/L1100.1299.9%
    NickelNimg/L1290.1199.9%
    LeadPbmg/L590.0899.9%
    CadmiumCdmg/L610.199.8%

    Inlet: raw plating wastewater, daily composite sample. Outlet: treated water after lime, caustic soda and trithiocarbonate precipitation and settling. One daily composite sample treated in laboratory jar tests; values are single results with measurement uncertainty (uncertainty not copied). Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.