Cyanide and nickel removal from a nickel plating bath by two cycles of alginate bead adsorption
A sample from a plating bath at a nickel electroplating factory near Vigo, very high in free cyanide, nickel and copper, was treated in the laboratory. The aim was to bring its pollutant load down towards the limits for discharge to a public sewage works.
Treatment line
- 01First adsorption cycleCalcium alginate hydrogel beads mixed with the raw wastewater for 30 minutes, at 1.5 volumes of beads per volume of wastewater. The beads are then removed and the water filtered.
- 02Second adsorption cycleThe once-treated water mixed with new beads at equal volumes.
What the source found
After two cycles the beads removed about 85% of free cyanide, 98% of nickel, 98% of copper and 93% of zinc from the raw wastewater. After the first cycle the water still held a high pollutant load and did not meet the discharge requirements, which is why a second cycle was added. Adding activated carbon or biodegraded grape marc to the beads gave only a slight gain, so plain alginate beads were preferred.
Batch flask tests on 10 mL portions of the real wastewater, with three determinations each, comparing three bead types, several bead to wastewater ratios, two successive cycles and contact times from 3 to 60 minutes.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Free cyanide | CN− | mg/L | 51,190 | 7,667 | 85% |
| Nickel | Ni | mg/L | 4,899 | 87.5 | 98% |
| Copper | Cu | mg/L | 1,904 | 38.7 | 98% |
| Zinc | Zn | mg/L | 58.8 | 3.9 | 93% |
| Lead | Pb | mg/L | not detected | ||
| Hexavalent chromium | Cr(VI) | mg/L | not detected | ||
| Total chromium | Cr | mg/L | not detected | ||
| pH | 12.45 |
Inlet: raw plating bath wastewater. Outlet: wastewater after the second bead adsorption cycle (bead to wastewater ratio 1:1). Means of three determinations in laboratory batch flask tests. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.