    Failing COD and ammonia removal at a small sewage works with sequencing batch reactors

    A municipal plant for 3,000 population equivalents with an average flow of 300 m³ per day, originally built as a sequencing batch reactor system with suspended activated sludge. From 2016 to 2018 it did not meet the national discharge limits for most parameters, so it was rebuilt within its existing tanks to run on aerobic granular sludge. The figures here describe the plant before that rebuild.

    Treatment line

    1. 01Fine screens and grit chamberMechanical pre-treatment of the incoming sewage.
    2. 02Equalisation tank100 m³; balances the inflow before the biological stage.
    3. 03Sequencing batch reactorsTwo tanks of 215 m³; before the rebuild each cycle ran aeration, denitrification, settling, sludge removal and filling.

    What the source found

    Before the rebuild the plant removed only about 71% of COD, 81% of BOD and 26% of ammonia, and in 2017 the outlet quality showed the plant was in an emergency state. After conversion to aerobic granular sludge in the same tanks, the outlet met the legal requirements at the same energy use.

    Yearly average inlet and outlet concentrations for 2016, 2017 and 2018, from unfiltered samples, averaged over the three years.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BOD5BOD5mg/L65312581%
    CODCODmg/L1,21435871%
    Suspended solidsTSSmg/L86611687%
    Ammonium nitrogenNH4-Nmg/L1188726%

    Inlet: raw sewage at the plant inflow. Outlet: treated water at the plant outflow. Averages of the yearly means for 2016, 2017 and 2018 before the rebuild, unfiltered samples. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.