Solids and grease removal from high-altitude sewage by settling and trickling filters
A municipal sewage plant in Yauli district, Huancavelica, Peru, sits at about 3,380 m and discharges its treated water straight to a river. It receives an average of about 706 m³/day. The plant has no disinfection or tertiary filtration, so effluent quality depends only on its physical and biological stages.
Treatment line
- 01Intake and pumping
- 02Screen chamber
- 03Grit chamber
- 04Two primary settling tanksFirst separation of solids.
- 05Grease trapSeparates oils and fats.
- 06Trickling filtersTwo filters with a 3 m gravel bed; sludge from the settlers and filters goes to a drying bed.
What the source found
Suspended solids fell by 73% and oils and grease by 41%, and the effluent met the national limits for these and for COD. The falls in COD and BOD were much smaller and not statistically significant, and the effluent did not meet the BOD limit. The filters were found to be heavily overloaded with organic matter, and the high altitude was seen as a further limit on biological treatment.
Eight 24-hour composite samples at the plant inlet and outlet between October 2019 and February 2020, during the rainy season.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Oil and grease | O&G | mg/L | 27.9 | 16.6 | 41% |
| Thermotolerant coliforms | FC | MPN/100 mL | 15,412.5 | 8,562.5 | 44% |
| BOD5 | BOD5 | mg/L | 763.2 | 732.9 | |
| COD | COD | mg/L | 125.1 | 114.8 | |
| Total suspended solids | TSS | mg/L | 390.6 | 105 | 73% |
| pH | 7.6 | 7.5 | |||
| Temperature | °C | 21.2 | 21.1 |
Inlet: raw sewage at the plant inlet. Outlet: treated effluent at the plant outlet. Means of eight 24-hour composite samples from October 2019 to February 2020, in the rainy season. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.