Aguato

    BOD and COD removal from town sewage by septic tank, horizontal and vertical flow reed beds

    A community-scale constructed wetland built in 2004 in Madhyapur Thimi municipality, Nepal, rated at 50 m³ a day. It treats community municipal wastewater from a wide area that includes all kinds of households and small factories. The treated water drains to the environment.

    Treatment line

    1. 01Septic tankSettling tank receiving the raw wastewater.
    2. 02Horizontal flow reed bedSub-surface flow bed planted with reeds.
    3. 03Vertical flow reed bedSub-surface flow bed planted with reeds; treated water is collected in a tank after it.

    What the source found

    This was the weakest of three wetlands surveyed, removing 56% of BOD and 64% of COD. The lower performance was put down to its larger size and higher organic load, a mixed municipal wastewater with factory discharges, limited oxygen in the beds and little maintenance. Phosphorus was barely reduced.

    Samples on two occasions at the inlet pipe before the septic tank and at the tank after the vertical flow bed, taken between 7 and 8 in the morning at peak flow.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH6.486.4
    Electrical conductivityECmS/cm1.211
    Total suspended solidsTSSmg/L4,762.557588%
    Total dissolved solidsTDSmg/L1,82075059%
    Total solidsTSmg/L6,582.51,32580%
    BODBODmg/L156.868.556%
    CODCODmg/L31011065%
    PhosphorusPmg/L0.960.933.1%

    Inlet: raw wastewater in the inlet pipe before the septic tank. Outlet: collection tank after the vertical flow reed bed. Means of two samples taken at morning peak flow. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.