Aguato

    Meeting the domestic discharge limits for BOD and COD by Imhoff tanks and trickling filters

    The municipal sewage plant of Khénifra, in the Béni Mellal-Khénifra region of central Morocco, has treated the town's domestic sewage since 2015 in two identical parallel lines. It was designed for about 153,000 population equivalents and about 12,000 m³/day, and in 2023 treated an average of 7,635 m³/day, well below its design load. The effluent goes to a seasonal watercourse, apart from a small flow used on site for cleaning and irrigating green areas.

    Treatment line

    1. 01Automatic screen6 mm bar spacing.
    2. 02Two grit channelsUnaerated channels, each 20 m long.
    3. 03Venturi flow channelMeasures the incoming flow.
    4. 04Four Imhoff tanksEight settling compartments that combine primary settling with anaerobic digestion of the sludge without energy input, which then goes to drying beds.
    5. 05Two trickling filters in parallelMedium-rate filters 30 m across and 3.9 m deep, packed with corrugated polyethylene media and aerated by natural draught, with clarified water recirculated to their inlet.
    6. 06Two secondary clarifiersEach 30 m across and 2.5 m deep, about 1,770 m³.

    What the source found

    The plant removed 90% of BOD, 87% of COD and 88% of suspended solids, and all effluent values were well within the national domestic discharge limits. Removals were slightly lower than at commissioning, when they were 96%, 93% and 97%; over the same years the incoming sewage became more dilute, and the plant ran at about a quarter of its design organic capacity. Electricity use stayed almost constant whatever the flow, and was low because the filters need no mechanical aeration.

    Weekly samples through 2023 at the inlet before the flow-measuring channel and after the secondary clarifiers, averaged by month and then over the year, compared with 2015 commissioning records.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BOD5BOD5mg L-13153290%
    CODCODmg L-16298187%
    Total suspended solidsTSSmg L-13013588%
    pH88
    Temperature°C19.421.2
    Dissolved oxygenDOmg L-10.15.6

    Inlet: raw wastewater at the plant inlet. Outlet: outlet of the secondary clarifiers. Annual means for 2023 of weekly samples averaged by month. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references