Aguato

    BOD and suspended solids removal from sewage by trickling filters and secondary clarifiers

    A municipal wastewater treatment plant with trickling filters in Ust-Kamenogorsk serves a titanium and magnesium works. Sewage first passes primary clarifiers; the part described here is the biological stage after them. The plant was also host to a pilot clarifier with a suspended sludge layer, fed with the trickling filter effluent.

    Treatment line

    1. 01Trickling filtersBiological treatment of the settled sewage on attached biofilm.
    2. 02Secondary clarifiersConventional settling of the biofilm sloughed from the trickling filters.

    What the source found

    Between the primary clarifier outlet and the secondary clarifier outlet, BOD fell by about 61% and suspended solids by about 55%. The conventional secondary clarifiers left much more suspended solids, BOD and nitrogen in the water than the pilot suspended-sludge-layer clarifier treating the same trickling filter effluent, whose effluent was judged comparable with sand filtration.

    Average quality of the effluent from each stage of the plant (primary clarifiers, trickling filters, secondary clarifiers) is compared with the effluent of the pilot clarifier.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    AmmoniaNH3mg/L20.51812%
    NitriteNO2−mg/L0.530.2357%
    NitrateNO3−mg/L0.9554.690%
    Dissolved oxygenDOmg/L4.25.9
    BOD5BOD5mg/L34.813.561%
    Total suspended solidsTSSmg/L582655%

    Inlet: effluent of the primary clarifiers. Outlet: effluent of the secondary clarifiers. Average values for each stage of the plant; number of samples and period not stated. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair. A parameter at 0% did not fall between the inlet and the outlet.