Phosphorus removal from domestic sewage by a sequencing batch reactor with iron electrolysis
A domestic sewage plant for 1,100 population equivalent with two sequencing batch reactors, receiving about 210 m³/day. The sewage is held in a stabilization tank, which also takes the supernatant from the sludge thickener, before it enters the reactors. Iron electrolysis was fitted to one reactor to see whether it could lower the phosphorus in the effluent; the other reactor ran without it as a control.
Treatment line
- 01Sequencing batch reactor173 m³ tank on a 6 hour cycle of three mixing and aeration steps, 1 hour settling and 2 hours discharge, taking 32 m³ of sewage per cycle.
- 02Iron electrolysis unit130 litre side unit with 32 iron electrodes; mixed liquor is pumped from the reactor through it and back, releasing iron that binds phosphate.
What the source found
Both reactors removed about 97% of suspended solids, 98% of BOD and 91% of total nitrogen, and iron electrolysis did not affect this. Biological phosphorus removal already took place, and iron electrolysis lowered effluent phosphorus further even at a small iron dose, with the chemical part of the removal in proportion to the iron added. The iron released was close to the weight lost by the electrodes.
Samples about every 10 days, in the stabilization tank for the inlet and at the reactor outlet, over four runs at increasing iron doses. BOD, suspended solids and nitrogen are averages over all four runs.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Suspended solids | TSS | mg/L | 120 | 3.8 | 97% |
| BOD | BOD | mg/L | 210 | 4 | 98% |
| Total nitrogen | TN | mg/L | 43 | 3.9 | 91% |
| Total phosphorus | TP | mg/L | 4.5 | ||
| Alkalinity | Alk | mg/L | 160 |
Inlet: sewage in the stabilization tank ahead of the reactors. Outlet: outlet of the reactor fitted with iron electrolysis. Means over four runs of samples taken about every 10 days. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.