Aguato

    BOD and suspended solids removal from city sewage by pre-aeration and activated sludge

    A sewage treatment plant in Hilla city, Babylon, Iraq, operating since 1982 and serving 50,000 people with an average inflow of 12,000 m³ a day. The sewer carries industrial wastewater as well as domestic sewage, and the treated water is discharged to a river. The site also has sediment tanks, re-aeration tanks, dilution tanks, storage tanks and a compact unit.

    Treatment line

    1. 01Pre-aeration tankSome organic matter is oxidised here.
    2. 02Conventional activated sludgeBiological treatment of carbon and nitrogen compounds.
    3. 03ChlorinationChemical treatment at the last stage.

    What the source found

    The plant's overall removal was put at more than 87% for BOD, 76% for COD and 82% for suspended solids, and its performance was judged satisfactory. Yearly removal varied, with BOD removal between 73% and 93% and COD removal between 71% and 87%. Even so, the six-year average quality of the treated water did not meet the national discharge standard.

    Daily composite samples of the inlet and outlet, analysed mostly by the plant's own laboratory over six consecutive years (2007 to 2012), summarised as six-year means and yearly removal figures.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    BOD5BOD5mg/L156.8426.06
    CODCODmg/L324.5571.04
    Total suspended solidsTSS190.3837.6680%
    ChlorideCl−549.44505.8
    pH7.527.58
    Temperature23.0522.25

    Inlet: raw sewage at the plant inlet. Outlet: treated effluent at the plant outlet. Six-year means of daily composite samples from 2007 to 2012. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references