Polyethylene glycol removal from sewage by moving bed biofilm reactor and lamella settling
A municipal sewage treatment plant in Karbala Governorate, designed for 10,000 people and 2,000 m³/day, was treating about 900 m³/day. The plant was studied because polyethylene glycol, a chemical used in surfactants, cosmetics and lubricants, was being released to the air around the aeration basin and left in the treated water. Sludge goes to an aerobic digester and a belt filter press.
Treatment line
- 01Preliminary treatment and equalizationRemoves large and small solids, grit and oil. It includes an aerated grit chamber, an oil separator and a 360 m³ equalization tank.
- 02Anoxic basinReceives nitrate returned from the aeration stage for pre-denitrification.
- 03Moving bed biofilm reactor aeration basin360 m³ with carrier media at 30% fill and a hydraulic retention time of 9.6 hours in operation.
- 04Lamella sedimentation basinInclined plates at 60 degrees with a retention time of 3 hours in operation.
What the source found
Over the year the plant removed 90% of COD and BOD, 95% of suspended solids, 93% of oil and grease and above 99% of hydrogen sulfide, meeting the national standard, while phosphate removal was low for lack of an anaerobic basin. Part of the polyethylene glycol was still emitted to air, mainly from the aeration basin in summer, or left in the effluent. Lowering the air flow, raising the media fill from 30% to 55% and returning sludge from the settler improved biodegradation, cut emissions and further lowered organic matter and nitrate in the treated water.
Samples at the plant inlet and outlet over one year from March 2022 to March 2023, followed by a process model calibrated on the plant and a six-month trial of operating changes from April to September 2023.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| COD | COD | mg/L | 455 | 44 | 90% |
| BOD5 | BOD5 | mg/L | 350 | 35 | 90% |
| Total suspended solids | TSS | mg/L | 280 | 15 | 95% |
| Nitrate | NO3− | mg/L | 0 | 35 | |
| Ammonium | NH4+ | mg/L | 28 | 0.15 | 99.5% |
| Phosphate as phosphorus | PO4-P | mg/L | 4 | 3 | |
| Hydrogen sulfide | H2S | mg/L | 40 | 0.18 | 99.6% |
| Oil and grease | O&G | mg/L | 45 | 3 | 93% |
| Polyethylene glycol in summer | mg/L | 8 | 0.8 | 90% | |
| Polyethylene glycol in winter | mg/L | 8 | 1.9 | 76% |
Inlet: wastewater at the plant inlet. Outlet: treated water at the plant outlet. One year of inlet and outlet samples, March 2022 to March 2023, before the operating changes. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.