BOD removal from household wastewater by an anaerobic baffled reactor and anaerobic filter
A community-run communal wastewater plant in Ngijo, Gunung Pati district, Semarang, Central Java, provided in 2012 under an urban sanitation programme. Household wastewater reaches it through a piped network and is treated before discharge to a receiving water. It was designed for 34 households but only 28 were connected, because of connection costs and low awareness, so it runs below its design load.
Treatment line
- 01Anaerobic baffled reactorAn improved septic tank with a row of baffle walls that force the wastewater to flow down and up.
- 02Anaerobic filterA concrete and brick septic tank with compartments fitted with filter media.
What the source found
The plant still removed about 95% of BOD, with 79% of suspended solids and 80% of oil and grease also removed, and the treated water met the provincial discharge standard. The long retention time that comes from the low number of connected households was given as a reason for the good result. The community group set up to run the plant was not working well and the structure was poorly maintained.
Laboratory tests of the wastewater at the plant inlet and outlet after more than two years of operation, alongside interviews and questionnaires with the operators and the connected households.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| BOD | BOD | mg/L | 357 | 15.72 | 96% |
| Total suspended solids | TSS | mg/L | 136 | 28 | 79% |
| Oil and grease | O&G | mg/L | 5.26 | 1.05 | 80% |
| pH | 7.13 | 6.7 |
Inlet: domestic wastewater at the plant inlet. Outlet: treated water at the plant outlet. Laboratory results at the inlet and outlet after more than two years of operation; the number of samples is not stated. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.