Aguato

    BOD and suspended solids removal from municipal sewage by an aeration tank and clarifiers

    A municipal sewage treatment plant in Bangalore, in Karnataka, designed for an average flow of 20,000 m³ per day (10,000 minimum, 40,000 peak). It treats raw city sewage that arrives without dissolved oxygen and with heavy organic and mineral loads on some days, and discharges the treated water to inland surface water.

    Treatment line

    1. 01Aeration tankActivated sludge stage that adds oxygen to the oxygen-free incoming sewage.
    2. 02Secondary clarifiersSettle the activated sludge and give the final effluent.

    What the source found

    The plant removed 92% of COD, 98% of BOD and 99% of suspended solids, but dissolved solids fell only 28%. The aeration tank alone removed less BOD than expected, which was put down to recycling of old sludge with few active microorganisms; recycling fresher sludge and running the aerators continuously were recommended.

    Composite samples at the plant inlet, the aeration tank outlet and the secondary clarifier outlet over seven days, 21 samples per point.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    pH7.2967.57
    Total dissolved solidsTDSmg/L2,146.191,534.7629%
    Total suspended solidsTSSmg/L468.14.67699.0%
    BOD5BOD5mg/L479.5211.2998%
    Dissolved oxygenDOmg/Lnil6.143
    CODCODmg/L789.966.2492%
    ChlorideCl−mg/L412.67380.487.8%
    SulfateSO42−mg/L41.2431.125%

    Inlet: raw sewage at the plant inlet. Outlet: outlet of the secondary clarifier. Means of 21 composite samples per point over seven days. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.