Aguato

    Organic load and solids removal from city sewage by screening and UASB reactors

    A municipal plant serving Floridablanca and part of Bucaramanga and Girón, in Colombia, treats part of the metropolitan area's domestic sewage, for an equivalent population of about 325,000 in 2015. It sits at 900 m above sea level. The screening and the anaerobic primary stage are described here; the UASB effluent then passes to two facultative lagoons that were not assessed.

    Treatment line

    1. 01Coarse screenBar spacing of 5 cm.
    2. 02Fine screensTwo screens with 6 mm and 3 mm spacing.
    3. 03Grit chamberOne unit with two modules.
    4. 04Four UASB reactors in parallelEach 40 m by 20 m and 4.1 m deep, about 3,300 m³, with a mean retention time of about 7.8 h; one reactor is split into two compartments, and the biogas is burned in flares.

    What the source found

    Over the nine years the reactors removed 52% of COD, 66% of BOD and 60% of suspended solids, and did not remove nitrogen or phosphorus, so the reactors alone could not meet the national discharge requirements and a further stage was needed. Efficiency dropped sharply in one year after toxic materials were wrongly let into the reactors during repairs, and recovered after the sludge was replaced. The older reactor design removed more organic matter than the newer split reactor.

    Nine years (2007 to 2015) of plant records from 24-hour composite samples taken twice a week at the inlet before screening and at each reactor outlet, averaged by month and year.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/l76652%
    BOD5BOD5mg/l37466%
    COD to BOD5 ratio22.9
    Suspended solidsTSSmg/l32860%
    Temperature°C2626
    pH7.77
    Total Kjeldahl nitrogenTKNmg/l62.562.4
    Total phosphorusTPmg/l10.210.2
    Volatile fatty acids to alkalinity ratio0.22

    Inlet: raw sewage at the plant inlet, before screening. Outlet: effluent of the four UASB reactors (average of the reactors). Annual averages of plant records from 24-hour composite samples taken twice a week from 2007 to 2015. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.

    Similar references