    COD and nitrogen removal from tannery wastewater by sequencing batch reactor and coagulation

    Real wastewater from a leather tannery in Barquisimeto, mixing the liming, chrome tanning and dyeing streams, was treated in a laboratory system. At the tannery the water had already been settled in balancing ponds, which lowered solids and let chromium settle out. The aim was an effluent that meets the national limits for discharge to water bodies.

    Treatment line

    1. 01Sequencing batch reactorA 2 litre glass reactor run on 12 hour cycles of anoxic filling, anoxic, aerobic and anoxic reaction, settling and decanting, seeded with sludge from a tannery treatment plant and run without any added carbon source.
    2. 02Coagulation and flocculationJar tests on the reactor effluent with ferric chloride as coagulant and waste brine from a salt works as aid, after making the water alkaline with sodium hydroxide, with 5 minutes of fast mixing, 60 minutes of slow mixing and 30 minutes of settling.

    What the source found

    The reactor removed only about half of the COD because most of what remained was not biodegradable, and it nitrified the ammonia almost fully but left organic nitrogen behind. Coagulation removed much of the leftover COD and organic nitrogen, so the combined line removed about 80% of COD, 82% of total nitrogen and above 99% of ammonia and met the national discharge limits for COD and total nitrogen. Redox, acidity and dissolved oxygen profiles in the reactor tracked the end of nitrification and denitrification and could be used to control the cycle.

    The combined system ran for 90 days on the pond-settled wastewater and twelve weekly samples were taken across both stages, with hourly samples and online probes inside the reactor cycle.

    Water in, water out

    ParameterSymbolUnitInletOutletRemoval
    CODCODmg/L1,54630380%
    Total Kjeldahl nitrogenTKNmg/L20023.488%
    Ammonium nitrogenNH4-Nmg/L1210.599.6%
    Organic nitrogenmg/L64.422.964%
    Nitrite plus nitrate nitrogenmg/L11.7
    Total nitrogenTNmg/L35.182%

    Inlet: pond-settled raw tannery wastewater fed to the reactor. Outlet: effluent after coagulation and flocculation. Averages of twelve weekly samples over 90 days of operation. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.