Sulfide and chromium removal from tannery wastewater by aerated pond and alum clarification
A medium-sized chrome tannery in the Akaki Kality sub-city of Addis Ababa has an average processing capacity of about 8,000 goat and sheep skins and 1,000 cattle hides a day. Its segregated beamhouse, chrome and dyeing wastewaters first enter an aerated equalisation basin meant to oxidise sulfide, and are then treated on site. The clarified effluent is released to a nearby river without disinfection.
Treatment line
- 01Aerated biological oxidation pondAerated pond meant to oxidise the organic matter measured as COD.
- 02Coagulation and flocculation basinAlum and ionic polymers are mixed in to remove organics, phosphate and chromium.
- 03Sedimentation basinSettles the flocs before discharge.
What the source found
Most parameters improved through the plant, but removal was only moderate and the effluent exceeded the national limits for COD, sulfide, total nitrogen and total chromium on both sampling days. No sign of nitrification was found, and alum was noted as not being a preferred coagulant for chromium. Changes in the raw wastewater with the skins being processed carried through to the effluent, so the treatment needs to be improved.
Two sampling events ten days apart in August, at the end of the wet season. Each sample was a composite of three points: the inlet samples were taken in the aerated equalisation basin and the outlet samples after the sedimentation basin, with further samples in the oxidation pond. Bacterial communities were also analysed by DNA sequencing.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 8 | 7.5 | |||
| Temperature | °C | 20.3 | 18.3 | ||
| Electrical conductivity | EC | mS/cm | 21.1 | 14.4 | |
| COD | COD | mg/L | 2,100 | 1,070 | 49% |
| Total dissolved solids | TDS | mg/L | 4,310 | 2,220 | 49% |
| Sulfide as sulfur | S2− | mg/L | 191 | 58 | 70% |
| Sulfate as sulfur | SO4-S | mg/L | 571 | 98 | 83% |
| Ammonia nitrogen | NH3-N | mg/L | 32 | 1.4 | 96% |
| Total nitrogen | TN | mg/L | 289 | 110 | 62% |
| Total chromium | Cr | mg/L | 37 | 4.8 | 87% |
Inlet: raw wastewater in the aerated equalisation basin. Outlet: effluent after the sedimentation basin. One composite sampling event in August, the first of two. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.