Chromium and COD removal from tannery finishing effluent by anaerobic reactor and membranes
A pilot unit in a university laboratory treated real effluent from the retanning and finishing of wet-blue leather at a tannery in Teutônia, Rio Grande do Sul. The aim was to see whether keeping biomass and large tannin molecules in the system with micro- and ultrafiltration would improve anaerobic treatment of this effluent. The feed rate was set at about 7.7 L/h.
Treatment line
- 01Feed storage tankHolds the tannery effluent pumped to the reactor.
- 02Completely mixed anaerobic reactor40 L working volume, kept at 35 °C in a water bath with automatic acid and alkali dosing, seeded with anaerobic sludge from a reactor at a gelatine plant.
- 03Ceramic microfiltrationTubular membranes with 0.2 µm pores that separate the biomass, which is returned to the reactor.
- 04Microfiltrate tankStores the microfiltration permeate that feeds the ultrafiltration.
- 05Ceramic ultrafiltrationTubular membranes with 0.005 µm pores that hold back large tannin molecules, whose reject returns to the microfiltrate tank.
What the source found
Chromium removal was above 95% in every stage, mostly because the metal bound to the biomass and the microfiltration kept that biomass in the reactor, so chromium built up in the reactor towards levels that inhibit methane production. COD removal over the whole line was 82% in the first stage and fell to 76% and 69% at the lower pressures, and suspended solids were fully retained by the microfiltration. Biogas production almost stopped within a few days because tannins, chromium and the microfiltration loop inhibited the methane-forming microbes, and membrane flux fell sharply through fouling.
Continuous operation in three stages with the membranes at 800, 600 and 400 kPa, with the feed, the microfiltrate and the ultrafiltrate analysed; the figures shown are the first-stage means, at 800 kPa, for the feed and the ultrafiltrate.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Chromium | Cr | mg/L | 44.49 | 2.16 | 95% |
| Total COD | COD | mg O2/L | 1,895.92 | 342.62 | 82% |
| Filtered COD | sCOD | mg O2/L | 1,100.58 | ||
| Dyes | mg/L | 258.96 | |||
| Tannins | mg/L | 135.25 | 15.97 | 88% | |
| Total solids | TS | mg/L | 1,943.64 | 714.69 | 63% |
| Volatile solids | VS | mg/L | 1,065.65 | 266.69 | 75% |
| Fixed solids | FS | 877 | 448.06 | 49% |
Inlet: tannery effluent fed to the anaerobic reactor. Outlet: ultrafiltration permeate. Means of the first operating stage, with the membranes at 800 kPa. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.