Water reuse from membrane bioreactor effluent by bag filtration and reverse osmosis
A full-scale municipal membrane bioreactor works in the City of Cape Town, Western Cape, serves the province's largest informal settlement and produces 18 megalitres of effluent per day. Its effluent fed a pilot plant that tested ultrafiltration, nanofiltration and reverse osmosis membranes for reuse in cooling and irrigation. The line listed here is the reverse osmosis line of the pilot.
Treatment line
- 01Bag filtersTwo bag filters of 5.0 and 1.0 micrometres between the feed pump and the high-pressure pump, to protect the membrane from large particles.
- 02Reverse osmosis elementSpiral-wound extra-low-energy polyamide element, with antiscalant dosing and, in some runs, sulfuric acid to keep the acidity constant; flushed daily with a biocide.
What the source found
Dissolved solids fell by 95% and the reverse osmosis permeate met all the reuse requirements for cooling and irrigation. Salt rejection was higher in the runs with acid dosing, and COD rejection reached 99% at the best settings. The reverse osmosis membrane used 1.42 times the energy of the nanofiltration and ultrafiltration membranes, and no energy recovery device was fitted.
Eight-hour once-through batch runs at different pH, flux and recovery settings, with eight-hour composite samples of the bioreactor effluent and the membrane permeate.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| Electrical conductivity | EC | mS/m | 56 | 37 µS/cm | |
| pH | 6.5 | 6.5 to 7.05 | |||
| Total dissolved solids | TDS | mg/L | 360 | 19 | 95% |
| COD | COD | mg/L | <20 | 2 | |
| Ammonium | NH4+ | mg/L | <0.4 | ||
| Phosphate | PO43− | mg/L | 2.6 | 0.45 | 83% |
| Nitrate | NO3− | mg/L | 13 | ||
| Turbidity | NTU | 0.25 | |||
| Temperature | °C | 25 | |||
| Ammonia | NH3 | mg/L | 0.17 | ||
| Phosphorus | P | mg/L | 0.21 |
Inlet: membrane bioreactor effluent feeding the pilot. Outlet: reverse osmosis permeate. Average membrane bioreactor effluent quality against the average reverse osmosis permeate quality over the batch runs. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.