Reuse of treated urban wastewater for turf irrigation by horizontal subsurface flow wetlands
A pilot constructed wetland in an urban park in Raffadali, in south-west Sicily, received urban wastewater that had already passed primary and secondary treatment at a municipal plant. On site the water first went to a 15 m³ storage tank and a static degreaser before being pumped into the wetland. The treated water was collected in four connected 5 m³ tanks and used for sprinkler irrigation of a bermudagrass turf trial.
Treatment line
- 01Horizontal subsurface flow constructed wetlandTwo parallel gravel beds, each 50 m long and 1 m wide, one planted with giant reed and one with umbrella sedge, run at a retention time of about 8.3 days and a loading of 6 cm per day.
What the source found
The bed planted with giant reed removed about 67% of COD, 62% of BOD, 69% of suspended solids, 51% of total nitrogen and 43% of phosphorus, with the other bed close behind. BOD and COD met the national irrigation reuse limits, while suspended solids did not always, and phosphorus exceeded its limit on average. Evapotranspiration reduced the outflow in summer, but the wetland still supplied a large volume of irrigation water in the dry months.
Grab samples at the wetland inlet and outlet pipes once a month from April to September in 2016, 2017 and 2018, 36 per bed, with the inflow and outflow measured by flow meter.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.41 | 7.1 | |||
| Temperature | °C | 15.1 | 14.8 | ||
| Dissolved oxygen | DO | mg/L | 1.21 | 1.01 | |
| Total suspended solids | TSS | mg/L | 39.8 | 12.4 | 69% |
| BOD5 | BOD5 | mg/L | 32.5 | 12.5 | 62% |
| COD | COD | mg/L | 55.6 | 18.6 | 67% |
| Total nitrogen | TN | mg/L | 21.3 | 10.4 | 51% |
| Total phosphorus | TP | mg/L | 8.62 | 4.9 | 43% |
| Total coliforms | TC | log10 CFU/100 mL | 4.44 | 3.44 | |
| Faecal coliforms | FC | log10 CFU/100 mL | 4.28 | 3.33 | |
| Faecal streptococci | log10 CFU/100 mL | 3.98 | 3.24 | ||
| Escherichia coli | log10 CFU/100 mL | 3.15 | 2.07 | ||
| Salmonella | CFU/100 mL | Absent | Absent |
Inlet: treated wastewater at the wetland inlet pipe. Outlet: outlet pipe of the bed planted with giant reed. Three-year averages of 36 monthly samples taken April to September in 2016, 2017 and 2018. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.