Water reuse from municipal secondary effluent by ultrafiltration
A containerised ultrafiltration unit was installed beside the secondary settling tanks of a municipal sewage treatment plant in Patras, Greece, and fed with part of the settled secondary effluent. The aim was water clean enough for reuse under national rules, with irrigation of a nearby municipal park as the main proposed use. The permeate flows on to the plant's existing chlorination, and the concentrate returns to the plant inlet.
Treatment line
- 01Stainless-steel prefilterProtects the membranes, with a pore size of 100 to 150 micrometres.
- 02Hollow-fibre ultrafiltrationEight modules in two parallel lines of four, 0.01 micrometre pores, with automatic air and water backwash and chemical cleaning, rated at 280 to 360 m³/day of permeate.
What the source found
The membrane cut turbidity by about 99% and suspended solids by more than 94%, and removed E. coli and enterococci completely, while COD fell by about 37% and dissolved salts passed through. Changing the permeate to feed ratio, cycle length and backwash time had no significant effect on permeate COD. After disinfection the permeate was judged suitable for every reuse class in national rules, including urban uses such as park irrigation.
Feed, permeate and concentrate were sampled on different operating days over about two months, giving 24 sets of samples, with fewer for some parameters.
Water in, water out
| Parameter | Symbol | Unit | Inlet | Outlet | Removal |
|---|---|---|---|---|---|
| pH | 7.45 | 7.42 | |||
| Electrical conductivity | EC | mS/cm | 1.95 | 1.96 | |
| Turbidity | NTU | 89.29 | <1 | 99.0% | |
| Total suspended solids | TSS | mg/L | 16.45 | <1 | 94% |
| Total solids | TS | mg/L | 831 | 597 | 28% |
| Total phosphorus | TP | mg/L | 1.86 | 1.69 | 9.1% |
| Total nitrogen | TN | mg/L | 3.62 | 3.25 | 10% |
| Ammonium nitrogen | NH4-N | mg/L | 0.3 | 0.29 | 3.3% |
| Nitrite nitrogen | NO2-N | mg/L | 0.13 | 0.13 | |
| Nitrate nitrogen | NO3-N | mg/L | 1.18 | 1.15 | |
| Chloride | Cl− | mg/L | 521 | 526 | |
| COD | COD | mg/L | 22.63 | 14.38 | 37% |
| BOD | BOD | mg/L | 6.67 | 4.78 | 28% |
| Sodium | Na | mg/L | 86.7 | 92.8 | |
| Potassium | K | mg/L | 16.15 | 19.66 | |
| Iron | Fe | µg/L | 87 | 63 | |
| Manganese | Mn | µg/L | 63 | 56 | |
| E. coli | CFU/100 mL | (6.12 ± 7.78) × 104 | not detected | ||
| Enterococci | CFU/100 mL | (1.87 ± 2.85) × 105 | not detected | ||
| Other coliforms | CFU/100 mL | (5.05 ± 4.47) × 104 | (5.35 ± 2.6) × 103 | 95% |
Inlet: settled secondary effluent fed to the membrane. Outlet: ultrafiltration permeate. Averages of up to 24 sample sets over about two months, fewer for some parameters. Values and units are as the published source prints them. Removal is worked out from the two values, or is the source's own figure where it prints no pair.